1.1.7.1.82 Overview of high-speed startup

[ Manual-related ]
Description
Please explain about the high-speed startup.
Field Remedy
Settings for the high-speed startup are as follows.
- Settings/Registration > Preferences > Timer/Energy Settings > Quick Startup Settings for Main Power
ON: High-speed startup is executed
OFF: High-speed startup is not executed (default)
[Reference] To realize faster startup, the power configuration has been changed to always supply power to the All-night Power Supply PCB. With this change, the
time to display the main menu after turning on the main power switch is shortened and the time until the screen can be operated on is also shortened.
This machine provides power to following PCBs even when in the main power switch is OFF.
- AC Driver PCB
- All-night Power Supply PCB
- Relay PCB
- Main Controller PCB 1
[Caution] Points to note when enabling the "Quick Startup Settings for Main Power" setting
If some of the MEAP applications are running on the device, the following problems will occur.
- The "Quick Startup Settings for Main Power" setting cannot be enabled.
If a MEAP application that restricts the device from shifting to deep sleep mode is running, even when the setting of "Quick Startup Settings for Main Power" is
enabled (ON), the device starts normally instead of quick startup.
In that case, the behavior of the MEAP application is not affected.
- Changes made in the Settings of a MEAP Application are not reflected.
If the startup setting "Quick Startup Settings for Main Power" is enabled (ON), even when the Main Power Supply Switch of the machine is turned OFF, a shutdown
process is not executed internally.
Therefore, in the case of a MEAP application where changes in settings are enabled when the device is restarted, changes in settings are not reflected just by chang-
ing the settings.
Follow either of the restart procedures shown below to enable the changes made in the settings.
a) Execute restart from remote UI.
b) Turn OFF the Main Switch, and then turn it ON within 20 seconds.
- After a recovery from Quick Startup, MEAP applications do not work properly.
MEAP applications that are scheduled to execute processes at specified times may not work properly after recovery from quick restart.
Unexpected problems such as the application executes a task at an unexpected timing may occur.
Problems may occur in the following two cases.
- In the case of "Schedule: Execute the task every 24 hours"
A schedule is set to start the specified task at the specified time and repeat "fixed-delay execution".
If execution is delayed for some reason, the delay time is ignored.
Problem: If 24 hours have passed since the last execution of the task, the task is executed only once.
The task may be executed at a timing other than the time the user expects it to be executed.
Reference sensor:
Outer Delivery Sensor (PS31)
Reference sensor:
Tray A (upper tray)
Upper Delivery Sensor (PS5)
Reference sensor:
Tray B (lower tray)
Lower Delivery Sensor (PS6)
Reference sensor:
Saddle assembly
Saddle Inlet Sensor (PS101)
Reference sensor:
Tray
Delivery Sensor (PI11)
Reference sensor:
Saddle assembly
Saddle Inlet Sensor (PI22)
Reference sensor:
Saddle Inlet Sensor (PS101/PI22)
Reference sensor:
Delivery Tray
Upper Tray Delivery Sensor( PS62)
Reference sensor:
Stack assembly
Paper Inlet Sensor 1 (PS11)
Reference sensor:
Timing Sensor (S5)
Chapter 1
Reference sensor:
Duplex Sensor 1 (PS24)
0031-7156
1-213