a job, and is not executed after that.
- Level 2
If the temperature becomes lower than the down sequence criterion temperature, the paper interval time is prolonged to lower the productivity to approx. 88%. Once
this control is implemented, the down sequence is not canceled during the job even if the temperature becomes higher than the criterion temperature.
- Level 3
If the temperature becomes lower than the down sequence criterion temperature, the paper interval time is prolonged to lower the productivity to approx. 75%. Once
this control is implemented, the down sequence is not canceled during the job even if the temperature becomes higher than the criterion temperature.
Down sequence judgment temperature table
Thin paper 2
Thin paper 1
Recycled paper 1
Recycled paper 2
Recycled paper 3
Plain paper 1
Plain paper 2
Thick paper 1
Thick paper 2
Thick paper 3
Thick paper 4
Thick paper 5
Thick paper 6
Coat paper 1
Coat paper 2
Coat paper 3
Coat paper 4
Coat paper 5
Coat paper 6
Matte Coated paper 1
Matte Coated paper 2
Matte Coated paper 3
Matte Coated paper 4
Matte Coated paper 5
Matte Coated paper 6
Textured paper 1
Textured paper 2
Textured paper 3
Textured paper 4
Textured paper 5
Textured paper 6
Textured paper 7
Textured paper 8
Postcard
Envelope
Transparency
Label paper
Field Remedy
After setting from Service Mode (Level 2) > COPIER > Option > IMG-FIX > DWN-TMP (Adjustment of down sequence temperature threshold value), turn OFF
and then ON the main power switch.
-4: -10 degrees Celsius
-3: -6 degrees Celsius
-2: -4 degrees Celsius
-1: -2 degrees Celsius
0: 0 degree Celsius (Default)
1: +3 degrees Celsius
Use 0 (Default) in the normal operation.
As the value is smaller, the machine is less likely to enter the down sequence and when -4 is set, the down sequence actually becomes OFF.
[Reference] Conditions in which the machine is likely to go into the down sequence (the center temperature is likely to be lowered):
- 500 sheets or more of continuous prints in small size
- LL or lower temperature environment
- Input voltage lower than the rated voltage

1.1.7.1.59 How to check total number of sheets fed through Fixing Assembly

[ Manual-related ]
Description
Please explain how to check the total number of sheets fed through the Fixing Assembly.
Paper type
Level 1
127 degrees Celsius
132 degrees Celsius
132 degrees Celsius
132 degrees Celsius
142 degrees Celsius
142 degrees Celsius
147 degrees Celsius
149 degrees Celsius
154 degrees Celsius
162 degrees Celsius
167 degrees Celsius
152 degrees Celsius
152 degrees Celsius
157 degrees Celsius
167 degrees Celsius
172 degrees Celsius
167 degrees Celsius
167 degrees Celsius
172 degrees Celsius
157 degrees Celsius
162 degrees Celsius
167 degrees Celsius
157 degrees Celsius
162 degrees Celsius
167 degrees Celsius
162 degrees Celsius
167 degrees Celsius
177 degrees Celsius
177 degrees Celsius
182 degrees Celsius
172 degrees Celsius
177 degrees Celsius
182 degrees Celsius
167 degrees Celsius
157 degrees Celsius
167 degrees Celsius
172 degrees Celsius
Level 2
Level 3
124 degrees Celsius
121 degrees Celsius
129 degrees Celsius
126 degrees Celsius
129 degrees Celsius
126 degrees Celsius
129 degrees Celsius
126 degrees Celsius
139 degrees Celsius
136 degrees Celsius
139 degrees Celsius
136 degrees Celsius
144 degrees Celsius
141 degrees Celsius
146 degrees Celsius
143 degrees Celsius
151 degrees Celsius
148 degrees Celsius
159 degrees Celsius
156 degrees Celsius
164 degrees Celsius
161 degrees Celsius
149 degrees Celsius
146 degrees Celsius
149 degrees Celsius
146 degrees Celsius
154 degrees Celsius
151 degrees Celsius
164 degrees Celsius
161 degrees Celsius
169 degrees Celsius
166 degrees Celsius
164 degrees Celsius
161 degrees Celsius
164 degrees Celsius
161 degrees Celsius
169 degrees Celsius
166 degrees Celsius
154 degrees Celsius
151 degrees Celsius
159 degrees Celsius
156 degrees Celsius
164 degrees Celsius
161 degrees Celsius
154 degrees Celsius
151 degrees Celsius
159 degrees Celsius
156 degrees Celsius
164 degrees Celsius
161 degrees Celsius
159 degrees Celsius
156 degrees Celsius
164 degrees Celsius
161 degrees Celsius
174 degrees Celsius
171 degrees Celsius
174 degrees Celsius
171 degrees Celsius
179 degrees Celsius
176 degrees Celsius
169 degrees Celsius
166 degrees Celsius
174 degrees Celsius
171 degrees Celsius
179 degrees Celsius
176 degrees Celsius
164 degrees Celsius
161 degrees Celsius
154 degrees Celsius
151 degrees Celsius
164 degrees Celsius
161 degrees Celsius
169 degrees Celsius
166 degrees Celsius