Canon imagePRESS C800 Series Troubleshooting Manual page 21

Hide thumbs Also See for imagePRESS C800 Series:
Table of Contents

Advertisement

and scanning them using the Duplex Color Image Reader Unit-H1 or the Auto Gradation Sensor-A1. Once this is complete, the machine automatically corrects the
irregularities. This recalibrates more accurately than the Quick Adjustment. Paper output as test pages are not counted as copy or print.
"Quick Adjustment": This is a quick and simple adjustment that is made to the gradation, density, and color settings of the machine. Recalibrations are made inter-
nally without outputting any test pages.
b) Full Adjustment
You can select the following two types of procedure for the full adjustment of automatic gradation adjustment.
- Use the Duplex Color Image Reader Unit-H1
In this procedure, you need to scan the printed test pages 3 times. You need to place test pages on the platen glass for scanning, but it takes shorter time for the
adjustment and the number of sheets required for the adjustment is 3 to 11 sheets of paper.
- Use the Auto Gradation Sensor-A1
In this procedure, the machine automatically performs the adjustment by printing test pages ten times. You do not need to set test pages for scanning, but it takes
longer time for the adjustment in comparison to using the Duplex Color Image Reader Unit-H1. The number of sheets required for the adjustment is 10 to 42 sheets
of paper.
[Caution]
- Full adjustment can be performed only if the optional Duplex Color Image Reader Unit-H1 or the Auto Gradation Sensor-A1 is attached.
- If both the Duplex Color Image Reader Unit-H1 and the Auto Gradation Sensor-A1 are attached, select the automatic gradation adjustment method you use in
"Select Method" beforehand. Select "Use Scanner" to use the Duplex Color Image Reader Unit-H1 or "Do Not Use Scanner" to use the Auto Gradation Sensor-A1.
To perform this procedure, you must log in to the machine as an administrator.
- Confirm that the following size and type of paper is set in the paper source before starting this procedure.
Size and type of paper is set in the paper source
Item
Size
Basis Weight/Finish/Whiteness
To improve the precision of the full adjustment, press "Number of Sheets to Output for Test Page" and increase the number of sheets to output for test page. The
following table shows the relationship between the setting value and actual number of sheets to output for test page.
- Number of sheets to output for test page when using the Duplex Color Image Reader Unit-H1
- Number of sheets to output for test page when using the Auto Gradation Sensor-A1.
Steps for Full Adjustment
1) Press Settings/Registration > Adjustment/Maintenance > Adjust Image Quality > Auto Adjust Gradation > press Full Adjustment > select the paper source in
which the paper type to use for test page is set > press OK.
When Using the Duplex Color Image Reader Unit-
H1
11" x 17" or A3
Hammermill Color Copy Digital (28lb. (105 g/m2))* or the paper type registered/selected as paper to
adjust
When Using the Auto Gradation Sensor-A1
13" x 19", 12" x 18", 12 5/8" x 17 11/16", 11" x 17",
or A3
Chapter 1
1-7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents