List Of Measured Values; Control Unit Counters - DeDietrich C 340 Series Installation And User Manual

High-efficiency floor-standing gas boiler with diematic evolution scb-01, diematic evolution scb-10
Table of Contents

Advertisement

10 Settings
Code
Display text
CP800
Commercial Dhw
CP801
Mode
CP802
CP803
CP804
CP810
DHW Backup
CP811
Capacity
CP812
CP813
CP814
CP820
DHW Production
CP821
Time
CP822
CP823
CP824
EP036
Sensor input
EP037
config
NP001
CascProdMan
Hys.High
NP002
CascProdMan
Hys.Low
NP003
CascProdManErr
Range
NP004
CascPFactorAlgo
Temp
10.4

List of measured values

Tab.98
Navigation for basic installer level
Level
Menu path
Basic installer
(1) See the column "Submenu" in the following table for the correct navigation. The counters are grouped in specific functionalities.
Tab.99
Counters at basic installer level
Code
Display text
AC001
Hours on mains
AC002
Service run hours
AC003
Hours since service Number of hours since the previous
AC004
Starts since service Number of heat generator starts since
114
C 340 / C 640
Description
Select the requested heating mode
for commercial domestical hot water
tank
Total electrical backup capacity
available to heat DHW tank
Maximum reserved time for complete
charging of the tank
Sets the general configuration of the
sensor input
Hysterese high for Producer Manager 0.5 °C - 10 °C
Hysterese low for Producer Manager
Maximum error gain for Producer
Manager
Proportional Factor for cascade with
Temperature algorithm
> Installation Setup > CU-GH13 > Submenu
Description
Number of hours that the appliance has
been on mains power
Number of hours that the appliance has
been producing energy since last service
servicing of the appliance
the previous servicing.
Range
0 = Preheat
1 = Heating
1 kW - 255 kW
1 HoursMinutes - 120
HoursMinutes
0 = Disabled
1 = DHW tank
2 = DHW tank top
3 = Buffer tank sensor
4 = Buffer Tank top
5 = System (cascade)
0.5 °C - 10 °C
0 °C - 10 °C
0 - 10
10.4.1

Control unit counters

> Parameters, counters, signals > Counters
(1)
Submenu
CIRCA 1
CIRCB 1
DHW 1
CIRCC 1
AUX 1
CIRCA 1
CIRCB 1
DHW 1
CIRCC 1
AUX 1
CIRCA 1
CIRCB 1
DHW 1
CIRCC 1
AUX 1
Analogue
input
Cascade
management
B
Cascade
management
B
Cascade
management
B
Cascade
management
B
Range
0 - 4294967295 Hours
0 - 131070 Hours
0 - 131070 Hours
0 - 4294967295
7762666 - v.02 - 29092020
Default
setting
0
0
0
0
0
12
12
12
12
12
60
60
60
60
60
0
3
3
10
1
Submenu
System Func­
tionality
Gas fired ap­
pliance
Gas fired ap­
pliance
Gas fired ap­
pliance

Hide quick links:

Advertisement

Table of Contents
loading