Scb-10 Expansion Pcb Settings - DeDietrich C 340 Series Installation And User Manual

High-efficiency floor-standing gas boiler with diematic evolution scb-01, diematic evolution scb-10
Table of Contents

Advertisement

Tab.91
Factory settings at installer level
Code
Display text
EP018
Status relay func.
EP019
Status relay func.
EP028
Function 10V-
PWM
EP029
Source 10V-PWM
Tab.92
Navigation for basic installer level
Level
Menu path
Basic installer
(1) See the column "Submenu" in the following table for the correct navigation. The parameters are grouped in specific functionalities.
7762666 - v.02 - 29092020
Description
Status relay function
Status relay function
Selects the function of the 0-10 Volt
output
Selects the source signal for the 0-10
Volt output
> Installation Setup > SCB-10 > Submenu
Range
0 = No Action
1 = Alarm
2 = Alarm Inverted
3 = Burning
4 = Not burning
5 = Reserved
6 = Reserved
7 = Service request
8 = Boiler on CH
9 = Boiler on DHW
10 = CH pump on
11 = Locking or Blocking
12 = Cooling mode
0 = No Action
1 = Alarm
2 = Alarm Inverted
3 = Burning
4 = Not burning
5 = Reserved
6 = Reserved
7 = Service request
8 = Boiler on CH
9 = Boiler on DHW
10 = CH pump on
11 = Locking or Blocking
12 = Cooling mode
0 = 0-10V 1 (Wilo)
1 = 0-10V 2 (Gr. GENI)
2 = PWM signal (Solar)
3 = 0-10V 1 limited
4 = 0-10V 2 limited
5 = PWM signal limited
6 = PWM signal (UPMXL)
0 = PWM
1 = Requested power
2 = Actual power
10.3.4

SCB-10 expansion PCB settings

Important
The table shows the factory setting for the parameters.
> Parameters, counters, signals > Parameters
(1)
10 Settings
Subme­
Default
nu
setting
Status
0
informati
on
Status
0
informati
on
0-10 volt
0
or PWM
out
0-10 volt
0
or PWM
out
C 340 / C 640
103