  • Page 1 EASYLIFE User Guide Oil/Gas-fired boiler ESSENCIO CF 22 CF 29 S U S T A I N A B L E C O M F O R T ®...
  • Page 2 Dear Customer, Thank you very much for buying this appliance. Please read through the manual carefully before using the product, and keep it in a safe place for later reference. In order to ensure continued safe and efficient operation we recommend that the product is serviced regularly. Our service and customer service organisation can assist with this.
  • Page 3: Table Of Contents

    Contents Contents Safety ................... . 5 General safety instructions .
  • Page 4 Contents Venting the heating system ..............32 Draining the heating system .
  • Page 5: Safety

    1 Safety Safety General safety instructions Tab.1 Operation Danger This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the ap­...
  • Page 6: Specific Safety Instructions

    1 Safety Specific safety instructions Tab.2 Electrical Danger of electric shock Before any work, switch off the mains supply to the boiler. Caution A disconnection method must be allowed in the fixed pipes in accordance with the rules on installation in force in the coun­ try.
  • Page 7 1 Safety Accessibility Important Keep the boiler accessible at all times. Caution Install the boiler in a frost-free environment. Important Allow the space required to correctly install the boiler. Refer to the Overall space needed for the boiler section in the in­ stallation and service manual.
  • Page 8 1 Safety Temperature Caution Do not touch the flue gas pipes. Depending on the boiler set­ tings, the temperature of the flue gas pipes can rise to over 60°C. Caution Do not touch radiators for long periods. Depending on the boiler settings, the temperature of the radiators may exceed 60 °C.
  • Page 9: Recommendations

    1 Safety Recommendations Important Keep this document close to the place where the appliance is installed. Important This manual can also be found on our internet site. Liabilities Tab.4 Manufacturer's liability Our products are manufactured in compliance with the requirements of the various Di­ rectives applicable.
  • Page 10: Symbols Used

    2 Symbols used Symbols used Symbols used in the manual This manual uses various danger levels to draw attention to special instructions. We do this to improve user safety, to prevent problems and to guarantee correct operation of the appliance. Danger Risk of dangerous situations that may result in serious personal injury.
  • Page 11: Technical Specifications

    3 Technical specifications Technical specifications Homologations 3.1.1 Certifications The boiler complies with current standards. CE identification number: 0085CQ0004 3.1.2 Oil categories Tab.5 Type of oil that can be used Maximum viscosity Domestic fuel oil with a low sulphur content (< 50 mg/kg) (EL). 6 mm /s at 20 °C Domestic fuel oil with a low sulphur content with up to 10% (<...
  • Page 12: Description Of The Product

    4 Description of the product Description of the product General description The floor-standing oil boilers in the CFU range have the following specifications: Heating only with possibility to produce domestic hot water by combining them with a domestic hot water tank High-efficiency heating Low polluting emissions Heating body in cast iron...
  • Page 13: Description Of The Home Screen (Direct Access)

    4 Description of the product Fig.4 1 Temperature measured by the outdoor temperature sensor (if present) 2 Day and time 3 General boiler status 4 Icons indicating the boiler status SYSTEME OK 14.1° Monday 11:51 MW-2001059-1 Tab.7 Icons indicating the boiler status Icons Description Steady icon: heating function activated...
  • Page 14: Description Of The Carousel (Quick Access)

    4 Description of the product Fig.7 Zone2 home screen (only if the 1 Temperature of the Zone2 (only if a room temperature sensor is SCB-04 optional PCB is connected) present in the zone) 2 Outdoor temperature 3 Zone2 name 4 Day and time 5 Operating mode 3.8°...
  • Page 15 4 Description of the product Accessible Description menus Chapter User settings Zones settings Changing the name and symbol of a zone Domestic Hot Water settings Modifying the domestic hot water set point temperatures CH function on Switching the central heating on/off DHW function on Switching domestic hot water production on/off Outdoor temperature...
  • Page 16: Operation

    5 Operation Operation Browsing in the menus Fig.10 Standby screen Press any key or turn the selector to turn on the backlight for the control panel screen. SYSTEM OK Important If no key is pressed for 3 minutes, the control panel backlight will 3.8°...
  • Page 17: Main Menu Quick Access Tree Structure

    5 Operation Tab.10 Display Available parameters Chapter Main home screen System holiday mode Periods of absence or going on holiday CH function on Switching the central heating on/off DHW function on Switching domestic hot water production on/off Forced summer On/Off Personalising the control panel Zone1 Set heating temperatures...
  • Page 18: Starting Up The Boiler

    5 Operation Accessible Description menus Chapter User settings Zones settings Changing the name and symbol of a zone Domestic Hot Water settings Modifying the domestic hot water set point temperatures CH function on Switching the central heating on/off DHW function on Switching domestic hot water production on/off Outdoor temperature Force summer mode: The heating is stopped.
  • Page 19: Frost Protection

    5 Operation For more information, see Selecting the operating mode, page 20 Periods of absence or going on holiday, page 24 Frost protection Caution The frost protection function does not work if the boiler is powered off. Caution The integrated protection system only protects the boiler, not the heating system.
  • Page 20: Settings

    6 Settings Settings Personalising the control panel It is possible to personalise the control panel by modifying the basic settings. 1. Go to the menu: System settings. Tab.14 Type of access Access path Direct access: from the main home screen Not available Quick access: from any screen →...
  • Page 21: Managing The Central Heating

    6 Settings 1. Go to the menu: Operating mode. Tab.16 Type of access Access path Direct access: from the main home screen → Select the page corresponding to the required zone → Select: Operating mode Quick access: from any screen Not available 2.
  • Page 22: Activating And Configuring A Timer Programme For Heating

    6 Settings 1. Go to the menu: Temporary heating temperature change. Tab.19 Type of access Access path Direct access: from the main home screen Not available Quick access: from any screen → Press the → Select: Temporary heating temperature change 2.
  • Page 23: Managing Domestic Hot Water Production

    6 Settings Managing domestic hot water production 6.4.1 Switching domestic hot water production on/off The domestic hot water production can be switched off. This can lead to energy savings, for example, during the summer period. 1. Go to the menu: Domestic Hot Water On/Off. Tab.22 Type of access Access path...
  • Page 24: Activating And Configuring A Timer Programme For Domestic Hot Water Production

    6 Settings 3. Set the desired temperature using the selector. 4. Go back to the main screen by pressing the back key 6.4.4 Activating and configuring a timer programme for domestic hot water production A timer programme can be used to vary the domestic hot water temperature depending on activities during the day.
  • Page 25: Personalising The Zones

    6 Settings 1. Go to the menu: System holiday mode. Tab.27 Type of access Access path Direct access: from the main home screen → Press the selector → Select: System holiday mode Quick access: from any screen → Press the →...
  • Page 26: Changing The Name And Symbol Of A Zone

    6 Settings Symbol Symbol Symbol allocation value Internal Boiler Tank Time Program 6.6.2 Changing the name and symbol of a zone The names and symbols of the various zones are factory-configured. It is possible to personalise the name and symbol for the installation zones. 1.
  • Page 27: Changing The Name Of An Activity

    6 Settings 6.7.2 Changing the name of an activity The name of the different activities is factory-set: Morning, Sleep, Home, Evening, Away and Custom. It is possible to personalise the name of the activities for all of the installation zones. 1.
  • Page 28: Monitoring The Energy Consumption

    6 Settings 2. Select the required activity: Tab.35 Activity Parameter Parameter name for the Zone1 or for the Zone2 (only if the SCB-04 optional PCB is connected) Sleep CP080 Room setpoint temperature of the user zone activity Can be set from 5 °C to 30 °C Home CP081 Room setpoint temperature of the user zone activity...
  • Page 29 6 Settings Tab.39 Available information CU-OH-04 PCB Software version Hardware version Version OBD Serial number Reference SCB-04PCB Software version Hardware version Version OBD Serial number Reference Display E-Pilot Software version Hardware version Version OBD Serial number Reference 7740500 - v02 - 12022021...
  • Page 30: Maintenance

    7 Maintenance Maintenance General instructions Maintenance operations are important for the following reasons: To guarantee optimum performance; Extend the boiler's service life; To provide an installation which offers the customer optimum comfort over time. Caution Have an inspection carried out and the flues swept at least once a year or more, depending on the regulations in force in your country.
  • Page 31: Chimney Sweep Instructions

    7 Maintenance 4. Open the fill valve. 5. Close the filling valve when the pressure gauge shows a pressure of 0.15 MPa (1.5 bar). 6. Put the boiler in heating mode. 7. When the pump has stopped, vent again and top up the water pressure.
  • Page 32: Venting The Heating System

    7 Maintenance Venting the heating system Fig.19 Any air in the boiler, pipes or valves must be vented in order to prevent annoying noises that may be generated during heating or when drawing water. 1. Open the valves of all the radiators and/or underfloor heating circuits connected to the system.
  • Page 33: Draining The Heating System

    7 Maintenance Draining the heating system Fig.20 It may be necessary to drain the central heating system if radiators need to be replaced, if there is a major water leak or if there is a risk of freezing. 1. Open the valves on all the radiators connected to the system. 2.
  • Page 34: Troubleshooting

    8 Troubleshooting Troubleshooting Resolving operating errors If the boiler malfunctions, a code is displayed on the main screen of the control panel. This code is important for the correct and rapid diagnosis of the type of malfunction and for any technical assistance that may be needed.
  • Page 35: Error Codes

    8 Troubleshooting Error code Message Description H02.16 Int CSU Timeout Internal CSU Timeout H02.25 ACI error ACI error H02.36 Funct device lost Functional device has been disconnected H02.37 Uncritic device lost Uncritical device has been disconnected H02.40 Function unavailable Function unavailable H02.48 Funct Gr Conf Fault Function Group Configuration Fault...
  • Page 36: Environmental

    9 Environmental Environmental Disposal and recycling Recycling Fig.21 Warning Removal and disposal of the boiler must be carried out by a qualified installer in accordance with local and national regulations. MW-3000179-03 Energy savings Energy-saving advice: Do not block ventilation outlets. Do not cover the radiators.
  • Page 37: 10 Warranty

    10 Warranty 10 Warranty 10.1 General We would like to thank you for buying one of our appliances and for your trust in our product. In order to ensure continued safe and efficient operation, we recommend that the product is regularly inspected and maintained. Your installer and our service department can assist with this.
  • Page 38 10 Warranty Tab.50 Italy As a manufacturer, we can by no means be held liable if the appliance is used incorrectly, is poorly maintained or not maintained at all, or is not installed correctly (it is your responsibility to ensure that installation and maintenance works are carried out by a qualified professional and by an after-sales service company, respectively).
  • Page 39: 11 Appendix

    11 Appendix 11 Appendix 11.1 Product fiche Tab.51 Product fiche for boiler space heaters Brand name - Product name CF 22 CF 29 Seasonal space heating energy efficiency class (Prated or Psup) Rated heat output Seasonal space heating energy efficiency Annual energy consumption Sound power level L indoors...
  • Page 40: Product Fiche

    11 Appendix 11.3 Product fiche Fig.22 The boiler's product fiche indicates the space heating energy efficiency of the product. Seasonal space heating energy effi ciency of boiler ‘I’ Temperature control Class I = 1%, Class II = 2%, Class III = 1.5%, Class IV = 2%, Class V = 3%, Class VI = 4%, from fi...
  • Page 41 11 Appendix The value of the seasonal space heating energy efficiency of the preferential space heater, expressed in %. The factor for weighting the heat output of preferential and supplementary heaters of a package as set out in the following table.
  • Page 42 11 Appendix 7740500 - v02 - 12022021...
  • Page 43 Original instructions - © Copyright All technical and technological information contained in these technical instructions, as well as any drawings and technical descriptions supplied, remain our property and shall not be multiplied without our prior consent in writing. Subject to alterations.
  • Page 44 57, rue de la Gare - F-67580 Mertzwiller 03 88 80 27 00 SERVICE CONSOMMATEURS 0 825 120 520 0,15 / min 03 88 80 27 99 www.dedietrich-thermique.fr VAN MARCKE NV 000 «БДP T » LAR Blok Z, 5 129164, Россия, г. Москва B- 8511 KORTRIJK Зубарев...