Status And Sub-Status - DeDietrich C 340 Series Installation And User Manual

High-efficiency floor-standing gas boiler with diematic evolution scb-01, diematic evolution scb-10
Table of Contents

Advertisement

10 Settings
Code
Display text
CM282
ZoneRTC
TcalcRoomStp
CM283
ZoneRTC
TcalcRoomStp
CM284
ZoneRTC
TcalcRoomStp
CM320
Time Start Backup
CM321
Time Start Backup
CM322
Time Start Backup
CM323
Time Start Backup
CM324
Time Start Backup
EM014
Tas voltage meas
EM023
Tas Actual Current
EM026
Input meas sensor
EM027
Input meas sensor
EM036
Av input meas
sensor
EM037
Av input meas
sensor
NM002
CascTempoBetwSt
age
Tab.124 AM012 - Status
Code
Display text
0
Standby
1
Heat Demand
2
Generator start
3
Generator CH
4
Generator DHW
144
C 340 / C 640
Description
Internal room temperature setpoint
calculated by the room temperature
controller of the zone
Internal room temperature setpoint
calculated by the room temperature
controller of the zone
Internal room temperature setpoint
calculated by the room temperature
controller of the zone
Estimated time before starting the
electrical backup for DHW tank Loading
Estimated time before starting the
electrical backup for DHW tank Loading
Estimated time before starting the
electrical backup for DHW tank Loading
Estimated time before starting the
electrical backup for DHW tank Loading
Estimated time before starting the
electrical backup for DHW tank Loading
Titan anti corrosion system voltage
measurement
Titan anti corrosion system
measurement of the actual current
Measurement of the input sensor of the
Smart Control Board
Measurement of the input sensor of the
Smart Control Board
Average measurement of the input
sensor of the Smart Control Board
Average measurement of the input
sensor of the Smart Control Board
Temporistation between start next stage
10.4.7

Status and sub-status

Explanation
The appliance is in standby mode.
A heat demand is active.
The appliance starts.
The appliance is active for central heating.
The appliance is active for domestic hot water.
Range
0 °C - 100 °C
0 °C - 100 °C
0 °C - 100 °C
0 Min - 1200 Min
0 Min - 1200 Min
0 Min - 1200 Min
0 Min - 1200 Min
0 Min - 1200 Min
0 V - 250 V
0 A - 655.35 A
-15 °C - 120 °C
-15 °C - 120 °C
-15 °C - 120 °C
-15 °C - 120 °C
0 Min - 60 Min
7762666 - v.02 - 29092020
Submenu
Direct zone
Mixed zone
High temp.
zone
Fan convector
zone
Direct zone
Mixed zone
High temp.
zone
Fan convector
zone
Direct zone
Mixed zone
High temp.
zone
Fan convector
zone
DHW
Commercial
Tank
DHW
Commercial
Tank
DHW
Commercial
Tank
DHW
Commercial
Tank
DHW
Commercial
Tank
TAS settings
TAS settings
Analogue
input
Analogue
input
Analogue
input
Analogue
input
Cascade
management
B

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents