Reading Out Measured Values - DeDietrich Innovens MCA 35 Installation And Service Manual

Wall-hung gas condensing boilers
Hide thumbs Also See for Innovens MCA 35:
Table of Contents

Advertisement

5. Commissioning
5.6

Reading out measured values

0
2
4
6
8
E
1
2
1
D
2
bar
#
F

% $
AUTO
J
I
STD
User level - Menu #MEASURES
Parameter
OUTSIDE TEMP.
(1)
ROOMTEMP. A
(1)
ROOMTEMP. B
(1)
ROOMTEMP. C
BOILER TEMP.
PRESSURE
(1)
WATER TEMP.
(1)
INST DWH TEMP.
(1)
STOR.TANK.TEMP
DCW TEMPERATURE Domestic cold water temperature
(1)
SWIMMING P.T.B
(1)
SWIMMING P.T.C
(1)
OUTLET TEMP. B
(1)
OUTLET TEMP. C
(1)
SYSTEM TEMP.
(1)
T.DHW BOTTOM
(1)
TEMP.TANK AUX
(1)
DHW A TEMP.
BACK TEMP
WIND SPEED
POWER
CURRENT (µA)
NB IMPULS.
RUNTIME
(1)
IN 0-10V
SEQUENCE
CTRL
(1) The parameter is only displayed for the options, circuits or sensors actually connected.
78
10
12
14
16
18
20
22
24
SUNDAY 11:45
!
:
<
C002219-D-04
Description
Outside temperature
Room temperature of circuit A
Room temperature of circuit B
Room temperature of circuit C
Water temperature in the boiler
Water pressure in the installation
Water temperature in the DHW tank
Instant hot water temperature
Water temperature in the storage tank
Water temperature of the swimming pool on circuit B
Water temperature of the swimming pool on circuit C
Temperature of the flow water in circuit B
Temperature of the flow water in circuit C
Temperature of the system flow water if multi-generator
Water temperature in the bottom of the DHW tank
Water temperature in the second DHW tank connected to the AUX circuit
Water temperature in the second DHW tank connected to circuit A
Temperature of the boiler return water
Fan rotation speed
Instantaneous boiler output (0%: Burner off or running at minimum output) %
Ionization current
Number of burner starts (not restartable)
The meter is incremented by 8 every 8 start-ups
Number of burner operation hours (not restartable)
The meter is incremented by 2 every 2 hours
Voltage at input 0-10 V
Control system sequence
Software control number
The various values measured by the appliance are displayed in the
#MEASURES menu.
1. To access user level: Press the > key.
2. Select the menu #MEASURES.
Turn the rotary button to scroll through the menus or
4
modify a value.
Press the rotary button to access the selected menu
4
or confirm a value modification.
¼ For a detailed explanation of menu browsing, refer
to the chapter: "Browsing in the menus", page 62.
MCA 35
Unit
°C
°C
°C
°C
°C
bar
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
rpm
µA
h
V
15/06/12 - 300022160-001-01