- Do not stock such products close to the boilers. If the boiler and/or peripheral equipment are corroded by such chloride or fluoride compounds, the contractual guarantee cannot be applied. 16/06/2009 - 300019729-001-C CBI-II / CBB 15 E...
(1 m x 1 m x 2 m) = 15 stere of logs 15 m (3 m x 2.5 m x 2 m) Multiplied by 2 for storage over 2 years (Drying of freshly cut wood) CBI-II / CBB 15 E 16/06/2009 - 300019729-001-C...
Optimally ensures the desired temperature on the premises and saves on fuel, Regulation whatever the outside temperature. Differential regulator Controls the domestic load pump. Radiators or underfloor heating Transfers the heat from the heating water to the premises. 16/06/2009 - 300019729-001-C CBI-II / CBB 15 E...
- Safety thermostat with manual reset (110 °C) - Safety battery (delivered from the factory) to be connected to the cold water by means of a control valve (option L33) - Safety valve (To be installed by the fitter) CBI-II / CBB 15 E 16/06/2009 - 300019729-001-C...
15. Flue gas thermostat for extractor fan Boiler CBB 15 E 13. General ON 1 / OFF 0 switch (DHW pump) 14. Boiler thermometer 15. Storage tank load pump thermostat (And/or return temperature elevating) - If connected CBI-II / CBB 15 E 16/06/2009 - 300019729-001-C...
8. Check the pumps: Turn the unlocking screw located at the centre of the pump with a screwdriver. Check that the air regulator flap is fully closed if the boiler reaches 90°C. 16/06/2009 - 300019729-001-C CBI-II / CBB 15 E...
4. Add logs to the combustion chamber. 5. Close the loading door. 6. Push the lever to close the air flap. Set the flue gas thermostat between Min and Max (when in operation) - except CBB 15 E. CBI-II / CBB 15 E 16/06/2009 - 300019729-001-C...
Do not remove the refractory components during cleaning. 3. Sweep the ashes through the smoke evacuation slit. 5.2 Maximum quantity of ashes CBI-II-20, 30, 40 CBB 15 E 2. Combustion chamber 3. Maximum quantity of ashes 4. Baffle 16/06/2009 - 300019729-001-C CBI-II / CBB 15 E...
- Check the squareness of the vanes of the fan. 5.5 Checking the doors (Around 1 time per month) Check the seal on the boiler doors 1 time per month. Have the fitter replace the seals if necessary. CBI-II / CBB 15 E 16/06/2009 - 300019729-001-C...
Precautions to take in the event of prolonged shutdown (one year or more) - The boiler and the chimney must be swept carefully. - Close the door of the boiler to prevent the internal circulation of air. 16/06/2009 - 300019729-001-C CBI-II / CBB 15 E...
Before informing the fitter of a fault, make a note of the following information: - Product type - Year of manufacture - Serial number This information can be found on the rating plate stuck to the side panel of the boiler. CBI-II / CBB 15 E 16/06/2009 - 300019729-001-C...
Belgium of the applicable legal dispositions on hidden defects. Italy The duration of our warranty is shown on the certificate delivered with the appliance. 16/06/2009 - 300019729-001-C CBI-II / CBB 15 E...
Page 16
All technical and technological information contained in these technical instructions, as well as any drawings and technical descriptions supplied, remain our property and shall not be multiplied without our prior consent in writing. Subject to alterations. 16/06/2009 DE DIETRICH THERMIQUE 57, rue de la Gare F- 67580 MERTZWILLER - BP 30...