Cu-Gh13 Control Unit Settings - C 640 - DeDietrich C 340 Series Installation And User Manual

High-efficiency floor-standing gas boiler with diematic evolution scb-01, diematic evolution scb-10
Table of Contents

Advertisement

10 Settings
Code
Display text
Description
PP007
Min anti-cy­
Minimum heat generator
cle time
holding time that can be
reached after a stop
PP012
Stabilization
Stabilization time after
time
heat generator start for
central heating
Tab.84
Navigation for basic installer level
Level
Menu path
Basic installer
(1) See the column "Submenu" in the following table for the correct navigation. The parameters are grouped in specific functionalities.
Tab.85
Factory settings at basic installer level
Code
Display text
Description
AP016
CH function
Enable central heating
on
heat demand processing
AP017
DHW func­
Enable domestic hot water
tion on
heat demand processing
AP074
Force sum­
The heating is stopped.
mer mode
Hot water is maintained.
Force Summer Mode
CP000
MaxZoneT­
Maximum Flow Tempera­
FlowSet­
ture setpoint zone
point
CP010
Tflow set­
Zone flow temperature
point zone
setpoint, used when the
zone is set to a fixed flow
setpoint.
CP080
User
Room setpoint tempera­
T.Room Ac­
ture of the user zone activ­
tivity
ity
CP081
User
Room setpoint tempera­
T.Room Ac­
ture of the user zone activ­
tivity
ity
CP082
User
Room setpoint tempera­
T.Room Ac­
ture of the user zone activ­
tivity
ity
CP083
User
Room setpoint tempera­
T.Room Ac­
ture of the user zone activ­
tivity
ity
CP084
User
Room setpoint tempera­
T.Room Ac­
ture of the user zone activ­
tivity
ity
CP085
User
Room setpoint tempera­
T.Room Ac­
ture of the user zone activ­
tivity
ity
96
C 340 / C 640
> Installation Setup > CU-GH > Submenu
Adjustment range
Subme­
nu
1 - 20 Min
Gas
fired ap­
pliance
0 - 180 Sec
Gas
fired ap­
pliance
10.3.2

CU-GH13 control unit settings - C 640

All tables show the factory setting for the parameters.
Important
The tables also list parameters that are only applicable if the boiler
is combined with other equipment.
> Parameters, counters, signals > Parameters
(1)
Adjustment range
Subme­
nu
0 = Off
Gas
1 = On
fired ap­
pliance
0 = Off
Gas
1 = On
fired ap­
pliance
0 = Off
Outdoor
1 = On
tempera­
ture
7 - 100 °C
Direct
zone
7 - 100 °C
Direct
zone
5 - 30 °C
Direct
zone
5 - 30 °C
Direct
zone
5 - 30 °C
Direct
zone
5 - 30 °C
Direct
zone
5 - 30 °C
Direct
zone
5 - 30 °C
Direct
zone
280
350
430
500
3
3
3
3
30
30
30
30
560
700
860
1000 1140 1300
1
1
1
1
1
1
1
1
0
0
0
0
80
80
80
80
90
90
90
90
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
7762666 - v.02 - 29092020
570
650
3
3
30
30
1
1
1
1
0
0
80
80
90
90
16
16
16
16
16
16
16
16
16
16
16
16