Synchronous input timing information
■Device number
Name
Synchronous input timing information X
■Description
When the synchronous timing control mode is used, the input timing for the synchronization cycle is stored.
The timing for when inputs are turned on from off or turned off from on in one synchronization cycle is stored.
When input changes multiple times in one synchronization cycle, the timing of the first input change is stored.
■Stored value
The elapsed time after the synchronization cycle timing (unit: 0.1s) is shown.
The following table lists the stored values.
Stored value
0 to 65534 (0000H to FFFEH)
65535 (FFFFH)
Module operation area
■Device number
Name
Module operation area
■Description
This area is intended for module operation.
RWw0
b0 to b9
b10
b11 to b15
■Error clear request flag (RWw0.b10)
For operation of the error clear request flag (RWw0.b10), refer to the following.
Page 177 Error flag (RWr0.b10)
Device number
RWr10 to RWr4F
Description
Shows that input changed at the stored timing.
Shows that input did not change within the synchronization cycle.
Device number
RWw0
Name
Use prohibited
Error clear request flag
Use prohibited
APPX
Appendix 2 Remote Register