Setup Procedure - Xantrex GPIB-M-HPD Operating Manual

Multichannel functionality for programmable dc power supplies
Table of Contents

Advertisement

Installation and Configuration
Basic Setup Procedure
Setup
For those who want more information, each step refers to more detailed procedures
located in subsequent sections.
Procedure
1. Power ON
2. Configure Computer Controller
3. Test
4. Configure power supply
1.
32
Power on the unit.
Configure the controller to match the power supply characteristics. The unit is
shipped with default GPIB address 2. Configure your controller to talk to
address 2.
Test the link by communicating with the power supply.
Example: Send the ID query "*IDN?" and ensure you get a response. Send the
command ":VOLT 2;:CURR 1" to set voltage to 2V and current limit to 1A.
1
(Using IBIC
this would be 'ibwrt ":volt 2;:curr 1"')
See
"Change Remote/Local Mode" on page 48
about Local/Remote modes.
If desired, configure the power supply with the desired power on settings or a
different GPIB address. (Be sure to change the controller address to match.)
See
"Power On Remote State" on page
56, and
"Power On Output State" on page
This text uses National Instruments' IBIC (Interface Bus Interactive Control) program commands
developed for their GPIB interface for computer controllers as examples only.
for information about changing
49,
"Set Up Power ON Defaults" on page
57.