Table 1.2 Specifications For Xfr 1200 W With Gpib-M Or Canbus - Xantrex GPIB-M-HPD Operating Manual

Multichannel functionality for programmable dc power supplies
Table of Contents

Advertisement

Features and Specifications
Specifications

Table 1.2 Specifications for XFR 1200 W with GPIB-M or CANbus

Models
Program Resolution
Voltage
Current
1
Program Accuracy
Voltage
Current
Readback Resolution
Voltage
Current
1
Readback Accuracy
Voltage
Current
Models
Program Resolution
Voltage
Current
1
Program Accuracy
Voltage
Current
Readback Resolution
Voltage
Current
1
Readback Accuracy
Voltage
Current
1. Apply accuracy specifications according to the following voltage program accuracy example:
Set a model XFR 20-60 power supply to 10 volts.
The expected result will be within the range of 10 volts ± 75mV ± 0.12% of the set voltage of 10 volts.
20
7.5-140
12-100
1.16mV
1.8mV
19.6mA
14mA
10mV
50mV
±0.12%
±0.12%
500mA
460mA
±0.1%
±0.1%
1.16mV
1.8mV
19.6mA
14mA
30mV
60mV
±0.12%
±0.12%
500mA
460mA
±0.1%
±0.1%
60-20
100-12
9.2mV
15.4mV
2.8mA
1.68mA
150mV
150mV
±0.25%
±0.35%
120mA
80mA
±0.1%
±0.1%
9.2mV
15.4mV
2.8mA
1.68mA
150mV
150mV
±0.25%
±0.35%
120mA
80mA
±0.1%
±0.1%
20-60
35-35
3.08mV
5.4mV
8.4mA
5.4mA
75mV
75mV
±0.12%
±0.3%
250mA
200mA
±0.1%
±0.1%
3.08mV
5.4mV
8.4mA
5.4mA
75mV
75mV
±0.12%
±0.3%
250mA
200mA
±0.1%
±0.1%
150-8
300-4
23.1mV
46.2mV
1.12mA
0.56mA
225mV
225mV
±0.35%
±0.35%
80mA
80mA
±0.1%
±0.1%
23.1mV
46.2mV
1.12mA
0.56mA
225mV
225mV
±0.35%
±0.35%
80mA
80mA
±0.1%
±0.1%
Operating Manual for Multichannel Functionality (GPIB-M)
40-30
6.2mV
4.2mA
75mV
±0.3%
150mA
±0.15%
6.2mV
4.2mA
75mV
±0.3%
150mA
±0.15%
600-2
92.4mV
0.28mA
250mV
±0.35%
50mA
±0.1%
92.4mV
0.28mA
250mV
±0.35%
50mA
±0.1%

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gpib-m-xfrGpib-m-xtGpib-m-xfr3Gpib-m-xpdGpib-m-xhr

Table of Contents