Specifications
The specifications in this section are warranted at 25°C ±5°C unless otherwise
specified. All specifications are subject to change without notice.
Table 1.1 Specifications for HPD 300 W with GPIB-M or CANbus
Models
Program Resolution
Program Accuracy
Readback Resolution
Readback Accuracy
1. Apply accuracy specifications according to the following voltage program accuracy example:
Release 2.1
Voltage
Current
1
Voltage
Current
Voltage
Current
1
Voltage
Current
Set a model HPD 15-20 power supply to 10 volts.
The expected result will be within the range of 10 volts ± 60mV ± 0.1% of the set voltage of
10 volts.
15-20
30-10
2.4mV
4.7mV
2.8mA
1.4mA
60mV
70mV
±0.1%
±0.1%
75mA
50mA
±0.12%
±0.12%
2.4mV
4.7mV
2.8mA
1.4mA
45mV
90mV
±0.3%
±0.3%
75mA
40mA
±0.12%
±0.12%
Features and Specifications
60-5
9.3mV
0.7mA
90mV
±0.12%
25mA
±0.1%
9.3mV
0.7mA
175mV
±0.3%
25mA
±0.1%