Remote Control Modes; Table 3.1 Power Supply Factory Defaults - Xantrex GPIB-M-HPD Operating Manual

Multichannel functionality for programmable dc power supplies
Table of Contents

Advertisement

Operation

Remote Control Modes

Remote Control Modes
The power supply must be in remote mode to execute commands. The remote mode
is indicated by the front panel remote status LED. A power supply will respond to
queries when in local mode, but will generate an error when a command is received.
GPIB equipped supplies will automatically transition from local to remote mode when
any command data is received. CANbus-only supplies may have to be put into remote
mode with a command before sending any other command. See
Remote/Local Mode" on page
The factory default power-on settings are given in

Table 3.1 Power Supply Factory Defaults

Power Supply
XFR or XHR
XPD
XT or HPD
You can change the default Remote/Local state, see
49.
If safety is an issue because the front panel control knobs may be set to hazardous
voltages at power on, contact the factory to order locking bushings for the knobs.
See your power supply's operating manual for details on using the power supply in
local mode.
46
48.
Default Remote State
Remote
Local
Local
Operating Manual for Multichannel Functionality (GPIB-M)
"Change
Table 3.1, on page
46.
Default Output State
(Shutdown)
OFF
ON
ON
"Power On Remote State" on page