the mesh is damaged and the Cooling Fan does not work, the Cooling Fan motor and cooling
element may overheat and cause fire.
8)
Set your PC's Power Options for 'Turn off the display', 'Turn off the hard disk', 'Standby mode' and
'Sleep mode' to 'Never'. Because the instrument continuously transmits and receives data from the
PC, hard disk power-down may cause malfunctions.
9)
The instrument automatically turns off the UV lamp and its operation when the instrument's door is
open. However, just in case it does NOT turns off when the door is open, please make sure the UV
light does not directly expose to your eyes and skin.

5. Precautions and warnings regarding product usage and maintenance

1)
This product must only be used for nucleic acid extraction and automatic aliquot. Do not use the
instrument for any use other than explicitly stated in the User Manual.
2)
Do not modify or delete instrument-related information installed within the instrument.
3)
Operate the LCD touchscreen using a non-sharp object. Nails and other sharp objects may damage
the product.
4)
The instrument UV lamp will only operate if the door is completely shut. Make sure the door sensor
is free of foreign materials or obstructions.
5)
Do not use powerful detergents or solvents to clean the outside of the instrument as this may cause
discoloration. If such chemicals are spilled on the instrument, immediately clean with a soft cloth.
6)
Do not keep the instrument in an environment with high humidity. Damage from storage in these
conditions is classified as water damage and is not covered by warranty. Also, damage arising from
this type of exposure may be irreparable.
7)
Disassembly and/or modification of the instrument voids the warranty and may be refused service.
8)
Do not unplug the power adapter from the instrument while the instrument is in use. This may cause
the instrument to break.
9)
If a burning smell is detected or the instrument seems to be excessively hot during operation,
immediately stop using the instrument and call your service representative.
10) Do not drop or impact the instrument. This is a direct cause of instrument damage and may void the
warranty.
11) Always verify that the Heating Block is in normal position before pulling out the Base Plate. If the
Base Plate is pulled out while the Heating Block is not in its normal, initialized position, the
interference in movement can cause Heating Block and other internal component damage and lead
to instrument malfunction. Since installed Buffer Cartridges obscure the view, re-initialize the
instrument or take out the Buffer Cartridges and visually inspect the position of the Heating Block
before pulling out the Base Plate.
12) Take caution not to damage the cooling fan mesh located on the front-bottom of the instrument. If
the mesh is damaged and the Cooling Fan does not work, the Cooling Fan motor and cooling
element may overheat and cause fire.
A4(210X297)
Fully Automated Nucleic Acid Extraction System
-4-
TM
ExiPrep
16 Dx