SI unit parameters
Parameter
No
(EDS parameter)
Power supply voltage
for control and input
1
monitor
(Pwr control monitor)
Power supply voltage
2
for output monitor
(Pwr output monitor)
Short circuit detection
3
(Monitor short circuit)
Restart after short
4
circuit (Restart after
short circuit)
Open circuit
5
Detection
(OC_Mon)
Output setting during
6
communication fault.
(Fault_MD )
Output setting during
7
communication idle
(Idle_MD)
Valve ON/OFF
8
counter
(Counter)
Setting value Contents
Enable monitoring of power
Enable
supply voltage for control and
input.
Disable monitoring of power
Disable
supply voltage for control and
input.
Enable monitoring of power
Enable
supply voltage for output
Disable monitoring of power
Disable
supply voltage for output
Enable valve short circuit
Enable
detection
Disable valve short circuit
Disable
detection
After short circuit has been
Auto
removed, the error will be cleared
automatically.
After short circuit has been
removed, the error will not be
Manual
cleared until the power supply is
reset.
Enable valve open circuit
Enable
detection
Disable valve open circuit
Disable
detection
During communication fault, clear
Clear
valve output.
During communication fault, hold
Hold
valve output.
During communication fault, turn
ForceOn
ON valve output.
During communication idle, clear
Clear
valve output.
During communication idle, hold
Hold
valve output.
During communication idle, turn
ForceOn
ON valve output.
If valve's ON/OFF counter
Enable
exceeds the set value, a
diagnostic error will be generated.
Diagnostic error will not be
Disable
generated
Set maximum counter value.
Val
Settable values are
(1 ~ 65000) x 1000 times
Setting
level
Unit
Unit
Unit
Unit
Channel
Channel
Channel
Channel
- 54 -
Setting method
Default
setting
By PLC By HT
O
O
O
O
O
O
O
O
O
O
O
O
X
O
O
O
X
O
O
X
O
O
X
O
65000