Address setting
Data rate setting
Note) If set to PGM, communication speed is set through DeviceNet ™ network.
It is necessary to set HW/SW switch to ON. (refer to "Setting 2 switch". )
Setting 1 switch
The switch settings become effective when power is applied to the unit.
V_SEL switch: A function to select the number of points occupied by valve outputs.
Select the output points (size) occupied by the SI unit.
Setting 1
No. 1
No. 2
OFF
OFF
OFF
ON
ON
OFF
ON
ON
Note) Please set the number of occupied valve points to more than the connected number of valves.
Address SW
x10
x1
0
0
0 (factory default)
0
1
0
2
...
...
6
2
6
3
6
4
...
...
9
9
Data rate SW
Communication speed
0
125 kbps (factory default)
1
2
3 ~ 9
Setting 1
Address
Setting 2
Description
Occupied bit for valve output is 32
Occupied bit for valve output is 24
Occupied bit for valve output is 16
Occupied bit for valve output is 8
Node address
1
2
...
62
63
Note)
PGM
250 kbps
500 kbps
Note)
PGM
Data rate
SI unit output data size
4 byte (factory default)
- 17 -
3 byte
2 byte
1 byte