D
CM35
Provide the cyclic redundancy checking for
30CCT.
NOTE:
When the opposite office does not
provide the cyclic redundancy
checking (CRC) function, set the
second data "1".
Provide the common signaling channel and
voice channel routes with No. 7 CCIS facili-
ties.
CM08
Provide station to station transfer over CCIS.
CM35
Assign a CCH number to each common signal-
ing channel and voice channel route.
Assign the kind of CCIS trunk (T1) to each
common signaling channel and voice channel
route.
NOTE:
When E1 (2 Mbps) is used, set the
second data to default (NONE).
CM30
Assign a Circuit Identification Code (CIC) to
each trunk number used for voice channel.
NOTE:
The Circuit Identification Code
(CIC) represents a circuit number to
designate a trunk (of each trunk
route) used as a voice channel in the
No. 7 CCIS network. A CIC should
not be assigned to a trunk used as a
Common Signaling Channel.
E
DESCRIPTION
RESET
Y=089
(1)
00-63: D channel Trunk Route No.
(2)
0 : To provide
1 : Not provided
Y=090
(1)
00-63: D channel Trunk Route No.
(2)
0: No. 7 CCIS
(1)
253
(2)
0 : Available
1 : Not available
Y=091
(1)
00-63: Trunk Route No.
(2)
00-63: CCH No.
Y=100
(1)
00-63: Trunk Route No.
(2)
11
NONE : No data
Y=35
(1)
000-511: Trunk No.
(2)
001-127: CIC
1-42
Chapter 1 CCIS FEATURES
CCIS BASIC PROGRAMMING
DATA
BLADE RESET
: CCIS Trunk (T1)
NWA-088654-001 Rev.1.0
94ch1002.fm