SMDR on RS-232C Programming
To send a billing information of center office to SMDR terminal via RS-232C interface, do the SMDR on
RS-232C Programming. For details of the programming, refer to Station Message Detail Recording
(SMDR) of Programming Manual.
START
CM02
Assign the system clock data.
CM08
Provide the system with Centralized Billing-
CCIS for Center Office.
Do not provide the system with Centralized
Billing-CCIS for Local Office.
CMA7
Assign the second data to 1 (Distant end is a
Local Office) to each CCIS channel.
A
DESCRIPTION
(1)
0: Calendar Year
(2)
2014-2099 (Ex. 2014)
(1)
1: Date
(2)
MM DD WW
MM : 01-12 (Month)
DD : 01-31 (Date)
WW: 00 (Sun)
01 (Mon)
02 (Tue)
03 (Wed)
04 (Thu)
05 (Fri)
06 (Sat)
(1)
2: Time
(2)
HH MM SS
HH : 00-23 (Hour)
MM: 00-59 (Minute)
SS : 00-59 (Second)
(1)
368
(2)
0: To provide
(1)
378
(2)
1 : Not provided
Y=03
(1)
00-63: CCIS channel No.
(2)
1: Distant end is Local Office
1-124
Chapter 1 CCIS FEATURES
CENTRALIZED BILLING-CCIS
DATA
NWA-088654-001 Rev.1.0
94ch1004.fm

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents