To provide an External TAS Indicator (To use the External Relay Interface on CPU):
START
CM30
Assign the TAS BUZZER to the required
trunks.
CM44
Assign the TAS Group number assigned by
CM30 Y=17 to a circuit number of the Exter-
nal Relay Interface on CPU.
CM59
Specify the indication pattern for the External
TAS Indicator.
END
DESCRIPTION
TRUNK ANSWER FROM ANY STATION-CCIS
Y=13 Day Mode/14 Night Mode
(1)
000-511: Trunk No.
(2)
01: TAS BUZZER
Y=00
(1)
312, 313: External Relay Interface on CPU
(2)
13 XX
XX: 00-63: TAS Group No. assigned by
(1)
00
(2)
01
02
03
07
NONE : 120 IPM
1-236
Chapter 1 CCIS FEATURES
DATA
CM30 Y=17
: 30 IPM
: 60 IPM
: 120 IPM
: Steady on
(0.25 seconds ON/OFF)
NWA-088654-001 Rev.1.0