LINK ALARM DISPLAY-CCIS

General Description
This feature provides an indication on external equipment when the CCIS link is connected/disconnected,
when the system is initialized.
Programming
START
CM05
Assign a Unit and Slot number to the DLC
blade.
NOTE:
CM10
Assign the station number connected to
PGD(2)-U10 ADP to its associated Physical
Port number.
CM12
Assign the Kind of PGD(2)-U10 station.
NOTE 1:
NOTE 2:
A
DESCRIPTION
BLADE RESET
When the PGD(2)-U10 ADP is
accommodated to the Remote Unit,
execute the system data copy by
CMEC Y=8 before executing the
blade reset.
Set the second data to "1" when
combining external relay with pag-
ing. Set the second data to "3" only
when using this feature.
When this command is set, PGD(2)-
U10 needs to reset (Blade Reset or
pull out and reconnect the modular
connector of the Multiline Termi-
nal).
Y=0
(1)
XX ZZ
XX: 01-50: Unit No.
ZZ : 01-18: Slot No.
(2)
10: DLC blade
Y=00
(1)
XX YY ZZ: Physical Port No.
XX: 01-50: Unit No.
YY: 01-18: Slot No.
ZZ : 01-32: Circuit No.
(2)
X-XXXXXXXX: Station No.
Y=65
(1)
X-XXXXXXXX: Station No.
(2)
1: Paging
3: External relay/External key/External
Hold Tone Source/Voice Response Sys-
tem
1-189
Chapter 1 CCIS FEATURES
LINK ALARM DISPLAY-CCIS