Reseizure Time For An External Line; Maximum Time Between Rings For An Incoming Call - Siemens HiPath 1100 Series Programming Manual

Table of Contents

Advertisement

Programming an External Line
Step by Step
0 5
0 5
36
...
Enter the length of time (05 to 99) for the Flash signal.
9 9
Take into account that 05 = 50 ms ... 99 = 990 ms.
Enter the number for the next external line available
or
Press this key.
#
Initial state for Programming Mode.

Reseizure Time for an External Line

There is a timeout for reseizing an external line. Once an
outgoing call has ended the line will remain blocked
during the specified timeout.
Required: Programming Mode must be active (*95
31994).
Enter the code for programming.
2 9
...
Enter the length of time (05 to 99) for the Flash signal,
9 9
where 05 = 500 ms (default) to 99 = 9900 ms.
Initial state for Programming Mode.
Maximum time between rings for an
incoming call
This consists of the time interval between two call
pulses from the local carrier (approximately 6 seconds).
After this pause, the system disconnects the external
line and is ready to receive new incoming calls.
In some countries the pause between pulses is longer
than 6 seconds. When this occurs, the length of time
can be set as desired.
Required: Programming Mode must be active (*95
31994).
Enter the code for programming.
1 7
Enter a length of time (05 to 20 seconds).
Initial state for Programming Mode.
Valid only for external analog lines.