Error Limit; Correction - Galil Motion Control DMC-18 2 Series User Manual

Table of Contents

Advertisement

OE
Profiler Off-On Error
YA
Step Drive Resolution (pulses / full motor step)
YB
Step Motor Resolution (full motor steps / revolution)
YC
Encoder Resolution (counts / revolution)
YR
Error Correction (pulses)
YS
Stepper Position Maintenance enable, status
A pulse is defined by the resolution of the step drive being used. Therefore, one pulse could be a full
step, a half step or a microstep.
When a Galil controller is configured for step motor operation, the step pulse output by the controller
is internally fed back to the auxiliary encoder register. For SPM the feedback encoder on the stepper
will connect to the main encoder port. Enabling the SPM mode on a controller with YS=1 executes an
internal monitoring of the auxiliary and main encoder registers for that axis or axes. Position error is
then tracked in step pulses between these two registers (QS command).
Where TD is the auxiliary encoder register(step pulses) and TP is the main encoder register(feedback
encoder). Additionally, YA defines the step drive resolution where YA = 1 for full stepping or YA = 2
for half stepping. The full range of YA is up to YA = 9999 for microstepping drives.

Error Limit

The value of QS is internally monitored to determine if it exceeds a preset limit of three full motor
steps. Once the value of QS exceeds this limit, the controller then performs the following actions:
The motion is maintained or is stopped, depending on the setting of the OE command. If OE=0 the
axis stays in motion, if OE=1 the axis is stopped.
YS is set to 2, which causes the automatic subroutine labeled #POSERR to be executed.

Correction

A correction move can be commanded by assigning the value of QS to the YR correction move
command. The correction move is issued only after the axis has been stopped. After an error
correction move has completed and QS is less than three full motor steps, the YS error status bit is
automatically reset back to 1 indicating a cleared error.
DMC-18x2
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
×
×
TP
YA
=
QS
TD
YC
YB
Chapter 6 Programming Motion • 97