All of the banks have the same configuration pattern as diagrammed above. For example, all banks
have Ux1 and Ux2 output optical isolator IC sockets, labeled in bank 0 as U01 and U02, in bank 1 as
U11 and U12, and so on. Each bank is configured as inputs or outputs by inserting optical isolator
IC's and resistor packs in the appropriate sockets. A group of eight LED's indicates the status of each
I/O point. The numbers above the Bank 0 label indicate the number of the I/O point corresponding to
the LED above it.

Digital Inputs

Configuring a bank for inputs requires that the Ux3 and Ux4 sockets be populated with NEC2505
optical isolation integrated circuits. The IOM-1964 is shipped with a default configuration of banks 2-
7 configured as inputs. The output IC sockets Ux1 and Ux2 must be empty. The input IC's are labeled
Ux3 and Ux4. For example, in bank 0 the IC's are U03 and U04, bank 1 input IC's are labeled U13
and U14, and so on. Also, the resistor pack RPx4 must be inserted into the bank to finish the input
configuration.
DMC-18x2
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
outputs
RP03 OUT
U03
IN
U01
OUT
D0
C6
RP01
Bank 0
Input Buffer IC's
U04
Output Buffer IC's
U02
Indicator LED's
Resistor Pack for
LED's
Appendices • 189