NEC Express5800/320Lb User Manual page 407

Hide thumbs Also See for Express5800/320Lb:
Table of Contents

Advertisement

PCI Board Status LED Indications
LED
Description
indications
Green
Duplex is specified,
however, the server
works in simplex
mode.
PCI board is properly
Off
installed and operates
in non-duplex mode
(AFT, ALB). (Does
not depend on
simplex or duplex.)
POST is operating or
the PCI board is
installed to operate in
the duplex mode.
The PCI board is not
installed yet, the PCI
board is installed
incorrectly, or the
power is not supplied.
Red
The PCI board is not
mounted; is mounted
incorrectly; or power
is not supplied.
Although the PCI
board is mounted, it
may be offline or not
be working.
Action
Specify duplex (AFT, ALB).
Specify an appropriate driver.
In non-duplex mode, no special problem occurs.
The system is operating normally in duplex mode.
Mount the PCI board correctly.
If the PCI board was not mounted, there is no
problem.
Check the condition of power unit.
Remount the PCI module.
Wait for a while until the indication changes. If the
indication unchanged, check the PCI board slot status
using NEC ESMPRO Manager.
Make the slot of the board installed from NEC
ESMPRO Manager online.
Mount the PCI board correctly.
System Upgrade 8-71