Environmental Requirements - Oracle Server X6-2 Installation Manual

Hide thumbs Also See for Server X6-2:
Table of Contents

Advertisement

Environmental Requirements

method. Ensure that the facility administrator or qualified electrical engineer who verifies the
grounding method for the building performs the grounding work.

Environmental Requirements

The following table lists the temperature, humidity, and altitude specifications, as well as
acoustic noise, vibration, and shock specifications.
TABLE 6
Environmental Specifications
Specification
Ambient temperature (Does
not apply to removable media)
Relative humidity
Altitude
Acoustic noise
Vibration
Shock
Set conditions to the optimal temperature and humidity ranges to minimize the chance of
downtime due to component failure. Operating the Oracle Server X6-2 for extended periods at
or near the operating range limits, or installing it in an environment when it remains at or near
nonoperating range limits could significantly increase hardware component failure. See also:
20
Oracle Server X6-2 Installation Guide • July 2020
Operating
■ Maximum range: 41°F to 95°F (5°C to 35°C) up to 2,953
feet (900 meters)
■ Optimal: 69.8°F to 73.4°F (21°C to 23°C)
Note -
Maximum ambient operating temperature is derated by
1 degree C per 300 meters of elevation beyond 900 meters, up
to a maximum altitude of 3,000 meters.
■ 10% to 90% noncondensing, short term 23°F to 113°F (–
5°C to 55°C)
■ 5% to 90% noncondensing, but not to exceed 0.024 kg of
water per kg of dry air (0.053 lbs water/2.205 lbs dry air)
Up to 9,840 feet (3,000 meters)
In China markets, regulations may limit installations to
Note -
a maximum altitude of 6,562 feet (2,000 meters).
■ Maximum condition: 7.1 Bels A weighted
■ Idle condition: 7.0 Bels A weighted
0.15 G (z-axis),
0.10 G (x-, y-axes), 5-500Hz swept sine
IEC 60068-2-6 Test FC
3.5 G, 11 ms half-sine
IEC 60068-2-27 Test Ea
Nonoperating
–40°F to 154°F (–40°C to 68°C)
Up to 93% noncondensing 95°F (35°C)
maximum wet bulb
Maximum 39,370 feet (12,000  meters)
Not applicable
0.5 G (z-axis),
0.25 G (x-, y-axes), 5-500Hz swept sine
IEC 60068-2-6 Test FC
Roll-off: 1.25-inch roll-off free fall,
front to back rolling directions
Threshold: 13-mm threshold height at
0.65 m/s impact velocity