Dalsa Linea SWIR GigE Series User Manual page 41

Ingaas line scan camera
Table of Contents

Advertisement

Rotary Encoder Input B
Source
GND
Line 2
Rotary Encoder Source
Activation
Rising Edge
Rotary Encoder Multiplier
Rotary Encoder Divider
Line Selector
Line 1
Line 2
Line Format
Single Ended
Open Collector
RS422
Line Mode
Input
Output
Input Line Detection Level
Threshold for 3.3V LVTTL
Threshold for 5V TTL
Threshold for 12V
Threshold for 24V
Line Status
False / True
Line Inverter
False / True
Input Line Debouncing
Period
Linea SWIR GigE Series Camera
rotaryEncoderInputBSource
GND
Line2
rotaryEncoderSrcActivation
RisingEdge
rotaryEncoderMultiplier
rotaryEncoderDivider
LineSelector
Line1
Line2
LineFormat
SingleEnded
OpenCollector
RS422
LineMode
Input
Output
lineDetectionLevel
Threshold_for_3V3
Threshold_for_5V
Threshold_for_12V
Threshold_for_24V
LineStatus
False / True
LineInverter
False / True
lineDebouncingPeriod
Selects which input line to assign to the Rotary
Encoder input B (also known as shaft encoder).
Note: that the Line Mode feature must be set to
Input. The list of supported input line sources is
device-specific.
Rotary Encoder Input B is not used.
Line2 is assigned to the Rotary Encoder Input B.
Specifies the signal edge(s) used to increment the
rotary encoder.
The rotary encoder uses the rising edge of the
source signal.
Specifies a multiplication factor for the rotary
encoder output pulse generator.
Specifies a division factor for the rotary encoder
output pulse generator.
Selects the physical line (or pin) of the external
device connector to configure.
Index of the physical line and associated I/O
control block to use.
Specify the current electrical format of the
selected physical input or output. Applies to all
physical lines. (RO)
The line is single ended input for
3.3V/5V/12V/24V or output for 3.3V LVTTL
The line is output as open collector.
The line accepts or sends RS422 level signals.
Reports if the physical line is an Input or Output
signal. (RO)
The line is an input line.
The line is an output line.
Specifies the voltage threshold required to
recognize a signal transition on an input line.
A signal below 1.5V will be detected as a Logical
LOW and a signal greater than 1.5V will be
detected as a Logical HIGH on the selected input
line.
A signal below 2.5V will be detected as a Logical
LOW and a signal greater than 2.5V will be
detected as a Logical HIGH on the selected input
line.
A signal below 5.0V will be detected as a Logical
LOW and a signal greater than 5.0V will be
detected as a Logical HIGH on the selected input
line.
A signal below 5.0V will be detected as a Logical
LOW and a signal greater than 5.0V will be
detected as a Logical HIGH on the selected input
line.
Returns the current status of the selected input or
output line. (RO)
Controls whether to invert the polarity of the
selected input or output line signal.
Specifies the minimum delay before an input line
voltage transition is recognized as a signal
transition.
Beginner
Beginner
Beginner
Operational Reference
1.00
Expert
DFNC
1.00
Expert
DFNC
1.00
Expert
DFNC
1.00
Expert
DFNC
1.00
1.00
Expert
1.00
Expert
1.00
Expert
DFNC
1.00
Expert
1.00
1.00
DFNC
39

Advertisement

Table of Contents
loading

Table of Contents