Acquisition and Transfer Control Feature Descriptions
The following table describes the parameters along with the view attribute and minimum camera
firmware version required. The Device Version column indicates which parameter is a member of
DALSA's Features Naming Convention (denoted by DFNC), versus the GenICam Standard Features
Naming Convention (SFNC not shown).
The Device Version number represents the camera software functional group, not a firmware
revision number. As the Linea SWIR GigE camera's capabilities evolve, the device version tag will
increase, identifying the supported function package. New features for a major device version
release will be indicated by
Display Name
Acquisition Status
Selector
Acquisition Trigger Wait
Acquisition Active
Acquisition Status
Acquisition Mode
Single Frame
Multi-Frame
Continuous
Acquisition Frame Count
Acquisition Arm Cmd
Acquisition Start Cmd
Acquisition Stop Cmd
74
Operational Reference
green text
for easy identification.
Feature & Values
AcquisitionStatusSelector
AcquisitionTriggerWait
AcquisitionActive
AcquisitionStatus
AcquisitionMode
SingleFrame
MultiFrame
Continuous
AcquisitionFrameCount
AcquisitionArm
AcquisitionStart
AcquisitionStop
Description
Selects the internal acquisition signal to read
using AcquisitionStatus.
Device is currently waiting for a trigger to
capture one or more frames.
Device is currently doing an acquisition of one or
more frames.
Reads the state of the internal acquisition signal
selected using the AcquisitionStatusSelector
feature.
Set the acquisition mode of the device. It
defines the number of frames to capture during
an acquisition and the way the acquisition stops.
One frame is captured for each AcquisitionStart
Command. An AcquisitionStop occurs at the end
of the Active Frame.
A sequence of frames is captured for each
AcquisitionStart Command. The number of
frames is specified by AcquisitionFrameCount
feature. An AcquisitionStop occurs at the end of
the Active Frame(s)
Frames are captured continuously with
AcquisitionStart until stopped with the
AcquisitionStop command.
Number of frames to be acquired in MultiFrame
acquisition mode.
Arms the device before an AcquisitionStart
command. This optional command validates all
the current features for consistency and
prepares the device for a fast start of the
acquisition. If not used explicitly, this command
is automatically executed at the first
AcquisitionStart but will not be repeated for
subsequent ones unless a data transfer related
feature is changed in the device. (WO)
Start image capture using the currently selected
acquisition mode. The number of frames
captured is specified by AcquisitionMode feature.
(WO)
Stops the Acquisition of the device at the end of
the current frame unless the triggerFrameCount
feature is greater then 1. (WO)
Linea SWIR GigE Series Camera
Device Version
& View
1.00
Expert
1.00
Expert
1.00
Beginner
1.00
Beginner
1.00
Guru
1.00
Beginner
1.00
Beginner