External Input AC Timing Characteristics
Conditions
Input Pulse 0 – 3V
Input Pulse 0 – 5V
Input Pulse 0 -12V
Input Pulse 0 – 24V
External Inputs: Using TTL / LVTTL Drivers
External Input current is limited by camera circuits to a maximum of 10 mA.
Linea SWIR GigE Series Camera
Description
Input Pulse width High
Input Pulse width Low
Max Frequency
Input Pulse width High
Input Pulse width Low
Max Frequency
Input Pulse width High
Input Pulse width Low
Max Frequency
Input Pulse width High
Input Pulse width Low
Max Frequency
Camera IO
Interface
10
9
( Input 2 )
8
7
( Input 1 )
6
5
(Common Ground)
4
3
2
1
Figure 55: External Inputs with TTL Sources
Min
1.3
1.7
315
0.6
2
247
0.39
3
160
0.39
4.9
103
LVTTL / TTL
User IO
Push-Pull
Power
Buffer
Imax = 10mA
Imax = 10mA
User IO
Ground
Unit
µs
µs
kHz
µs
µs
kHz
µs
µs
kHz
µs
µs
kHz