Dalsa Linea SWIR GigE Series User Manual page 42

Ingaas line scan camera
Table of Contents

Advertisement

Line Electrical Termination
Disabled
Enabled
Output Line Source
Off
Software Controlled
Pulse on: Start of Frame
Pulse on: Start of Line
Pulse on: Start of Exposure
Pulse on: End of Exposure
Pulse on: Start of Readout
Pulse on: End of Readout
Pulse on: Valid Line Trigger
Pulse on: Invalid Line
Trigger
Pulse on: Start of Acquisition
Pulse on: End of Acquisition
Pulse on: End of Timer 1
Pulse on: End of Counter 1
Pulse on: Input Line 1 Event
Pulse on: Input Line 2 Event
Pulse on: Rotary Encoder 1
Pulse on: Software
Command
Frame Trigger
Frame Valid
Exposure Active
Line Active
Smart Strobe Active
Output Line Pulse Signal
Activation
Rising Edge
Falling Edge
40
Operational Reference
lineElectricalTermination
Disabled
Enabled
outputLineSource
SoftwareControlled
PulseOnStartofFrame
PulseOnStartofLine
PulseOnStartofExposure
PulseOnEndofExposure
PulseOnStartofReadout
PulseOnEndofReadout
PulseOnValidLineTrigger
PulseOnInvalidLineTrigger
PulseOnStartofAcquisition
PulseOnEndofAcquisition
PulseOnTimer1End
PulseOnCounter1End
PulseOnInput1
PulseOnInput2
PulseOnRotaryEncoder1
PulseOnSoftwareCmd
FrameTriggerActive
FrameActive
ExposureActive
ReadoutActive
SmartStrobeActive
outputLinePulseActivation
RisingEdge
FallingEdge
Controls if the electrical termination of the
selected line is enabled or disabled.
Disables electrical line termination for the
selected line.
Enables electrical line termination for the selected
line.
Selects which internal signal or event driven pulse
or software control state to output on the selected
line. Note: The Line Mode feature must be set to
Output. The List of supported output line sources
is product-specific. The
provides details and timing diagrams for the
supported trigger modes.
Off
Line output is Open.
The OutputLineValue feature changes the state of
the output.
Generate a pulse on the start of the Frame Active
event.
Generate a pulse on the start of the Line Active.
Generate a pulse on the ExposureStart event.
This option is typically used to trigger a strobe
light.
Generate a pulse on the ExposureEnd event. This
option is typically used to trigger a strobe light.
Generate a pulse on the ReadoutStart event.
Generate a pulse on the ReadoutEnd event.
Generate a pulse on the LineTrigger event.
Generate a pulse on the Invalid LineTrigger event.
Generate a pulse when the AcquisiontStart event
occurs.
Generate a pulse when the AcquisiontStop event
occurs.
Generate a pulse on the TimerEnd 1 event.
Generate a pulse on the CounterEnd 1 event.
Generate a pulse on the Input signal 1 event
Generate a pulse on the Input signal 2 event
Generate a pulse on the Rotary Encoder 1 event.
Generate a pulse on the Input of a Software
Command.
Generate a signal that is active when the frame
trigger is active.
Generate a signal that is active when the Frame is
active.
Generate a signal that is active when the
Exposure is active.
Generate a signal that is active when the line
valid is active.
Generate a signal that is active when the Readout
or the ExposureDelay are active. The smart
strobe only works when triggerLineCount is
greater than 1
Specifies the input line activation mode to trigger
the OutputLine pulse.
Specifies that the trigger is considered valid on
the rising edge of the source signal.
Specifies that the trigger is considered valid on
the falling edge of the source signal.
Event Control section
Linea SWIR GigE Series Camera
1.00
Expert
DFNC
1.00
Beginner
DFNC
1.00
Beginner
DFNC

Advertisement

Table of Contents
loading

Table of Contents