Dalsa Linea SWIR GigE Series User Manual page 16

Ingaas line scan camera
Table of Contents

Advertisement

Connecting the Linea SWIR GigE
Camera
GigE Network Adapter Overview
The host computer requires an available Gigabit network port. Typically, Windows will recognize
the Gigabit NIC automatically when Windows boots and assign an IP address.
When installing a high performance Gigabit NIC adapter, review the NIC documentation concerning
any specific driver required for your operating system.
Note: Teledyne DALSA engineering has seen cases where a PCI Express bus Gigabit NIC has better
overall performance than the same NIC hardware in PCI bus format.
Connect the Linea SWIR GigE Camera
Connecting a Linea SWIR GigE camera to a network system is independent of whether the
Teledyne DALSA's Sapera LT package or a third party package is used.
Before connecting power to the camera, test the power supply. Power supplies must meet the
requirements defined in section Camera Power-up Configuration.
Connect Linea SWIR GigE to the host computer with a GigE network adapter or an Ethernet
switch via a CAT5e or CAT6 Ethernet cable.
Note: Cable should be longer that 1 meter (3 feet) and less than 100 meters (328 feet) long.
Once communication with the host computer has begun, the automatic IP configuration
sequence will assign an LLA IP address as described in section Linea SWIR GigE IP
Configuration Sequence or a DHCP IP address if a DHCP server is present on your network.
The diagnostic LED will be initially red then switch to flashing blue while waiting for IP
configuration. See Camera Status LED Indicator for Linea SWIR GigE LED display descriptions.
The factory defaults for Linea SWIR GigE is Persistent IP disabled and DHCP enabled with LLA
always enabled as per the GigE Vision specification. For additional information, see IP
Configuration Mode Details. See the next section Connectors for an overview of the interface.
Note: If Camera fails to connect, refer to section 'Camera Fails to Establish Connection with
Host PC or Persistent IP section.