Counter and Timer Control Feature Description
The following Counter and Timer Block Diagram describes the parameters along with their view
attributes and minimum camera firmware version required. The Device Version column indicates
which parameter is a member of the DALSA Features Naming Convention (indicated by DFNC),
versus the GenICam Standard Features Naming Convention (SFNC not shown).
The Device Version number represents the camera software functional group, not a firmware
revision number. As Linea SWIR GigE capabilities evolve the device version will increase,
identifying the supported function package. New features for a major device version release will be
indicated by
green text
Display Name
Counter Selector
Counter 1
Counter Mode
Off
Active
Counter Status
Counter Idle
Counter Trigger Wait
Counter Active
Counter Completed
Counter Overflow
Counter Start Source
Off
Acquisition Start
Exposure Start
Exposure End
Frame Start
Rejected Trigger
Line 1
Line 2
Timer 1 End
Counter 1 End
Counter Start Line
Activation
Linea SWIR GigE Series Camera
for easy identification.
Feature & Values
counterSelector
Counter1
counterMode
Active
counterStatus
CounterIdle
CounterTriggerWait
CounterActive
CounterCompleted
CounterOverflow
counterStartSource
AcquisitionStart
ExposureStart
ExposureEnd
FrameStart
InvalidTrigger
Line1
Line2
Timer1End
Counter1End
counterStartLineActivation
Description
Selects the counter to configure.
Select counter 1.
Selects the counter mode. The selected Counter is
either Active or Disabled. When Disabled, the
Counter can be configured.
Off
The selected Counter is Disabled.
The selected Counter is Enabled.
Returns the current state of the counter. (RO)
The counter is idle.
The CounterStartSource feature is set to off.
The counter is waiting for a start trigger.
The counter is counting for the specified duration.
The counter reached the CounterDuration count.
The counter reached its maximum possible count.
Select the counter start source. Counter
increments from 0 to the value of the
counterDuration feature.
Off
Counter is stopped.
Counter starts on the reception of the Acquisition
Start event.
Counter starts on the reception of the Exposure
Start event.
Counter starts on the reception of the Exposure
End event.
Counter starts on the reception of the Frame Start
event.
Counter starts on the reception of the Invalid
Trigger.
Counter starts on the specified transitions on Line
1.
Counter starts on the specified transitions on Line
2.
Counter starts on the reception of the Timer 1 End
event.
Counter starts on the reception of the Counter 1
End event.
Select the activation mode of the input line trigger
which starts the counter. This is only applicable
when the counterStartSource feature selects a
physical Line.
Device Version
& View
Operational Reference
1.00
Expert
DFNC
1.00
Expert
DFNC
1.00
Expert
DFNC
1.10
Expert
DFNC
1.00
Expert
DFNC
45