Exposure Delay
Gain
Flat Field Correction
Output Lines
Features Activation Mode
Off
Active
Preset Configuration
Selector
Exposure Time
Gain
Flat Field Correction
Current Active Set
User Flatfield 1
User Flatfield 2
User Flatfield 3
User Flatfield 4
Line Selector
Line 3 or pin 6
Line 4 or pin 8
Output Line Source
Off
Software Controlled
Pulse On: Start of
Exposure
Output Line Value
Active
Inactive
Exposure Delay
68
Operational Reference
ExposureDelay
FlatFieldCorrection
OutputLineControl
cP_FeaturesActivationMode
cP_PresetConfigurationSelector
cP_ExposureTime
cP_Gain
cP_flatfieldCorrectionCurrentActiveSet
UserFlatfield1
UserFlatfield2
UserFlatfield3
UserFlatfield4
cP_LineSelector
cP_OutputLineSource
SoftwareControlled
PulseOnStartofExposure
cP_OutputLineValue
cP_ExposureDelay
The cP_FeaturesActivationMode feature
controls the exposure delay.
Gain
The cP_FeaturesActivationMode feature
controls the Gain.
The cP_FeaturesActivationMode feature
controls the flat field correction.
The cP_FeaturesActivationMode feature
controls the output lines.
Enables the selected feature to be part of the
cycling. When activating the selected feature,
this will automatically set the corresponding
standard camera feature to read only.
Off
Exclude the selected feature from the cycling.
Active
Activate the selected feature in the cycling.
Selects the cycling preset to configure.
Sets the exposure time (in microseconds) for
the selected set.
Sets the selected gain as an amplification
factor applied to the image.
Specifies the current set of Flat Field
coefficients to use.
Sets User Flat Field 1 coefficient table as the
current Flat Field.
Sets User Flat Field 2 coefficient table as the
current Flat Field.
Sets User Flat Field 3 coefficient table as the
current Flat Field.
Sets User Flat Field 4 coefficient table as the
current Flat Field.
Selects which physical line (or pin) of the
external device connector to configure.
Line2
Index of the physical line and associated
Output control block to use.
Line4
Index of the physical line and associated I/O
control block to use.
Selects which internal signal, or event driven
pulse, or software control state to output on
the selected output line.
Off
Line output is Open.
The OutputLineValue feature changes the
state of the output.
Generate a pulse on the ExposureStart event.
This option is typically used to trigger a strobe
light.
Sets the output state of the selected Line if
the outputLineSoftwareLatchControl = OFF.
OutputLineSource must be
SoftwareControlled. If the
outputLineSoftwareLatchControl = Latch , the
state of the pin will change with the
outputLineSoftwareCmd command.
Active
Sets the Output circuit to closed.
Inactive
Sets the Output circuit to open.
Sets the exposure delay (in microseconds) for
the selected set.
Linea SWIR GigE Series Camera
V1.00
Expert
DFNC
V1.00
Expert
DFNC
V1.00
Expert
DFNC
V1.00
Expert
DFNC
V1.00
Expert
DFNC
V1.00
Expert
DFNC
V1.00
Expert
DFNC
V1.00
Expert
DFNC
V1.00
Expert
DFNC

Advertisement

Table of Contents
loading

Table of Contents