Flat field Calibration
Target (in DN)
Flat Field Calibration
Sample Size
Calibrate FPN
No Error
Calibration Failed
Camera Busy
Timeout Error
Memory Error
Target Error
Calibrate PRNU
No Error
Calibration Failed
Camera Busy
Timeout Error
Memory Error
Target Error
Save Calibration
Reset Coefficients
Flat Field Correction
Pixel X Coordinate
Flat Field Correction
Gain
Flat Field Correction
Offset
Processing Path Bits Per
Pixel
Flat Field Algorithm
Buffer Format
Mono 8
Flat Field Algorithm
Buffer Width
Linea SWIR GigE Series Camera
flatfieldCalibrationTarget
flatfieldCalibrationSampleSize
flatfieldCalibrationFPN
GenericError
BusyError
TimeoutError
MemoryError
TargetError
flatfieldCalibrationPRNU
GenericError
BusyError
TimeoutError
MemoryError
TargetError
flatfieldCalibrationSave
flatfieldResetCoefficients
flatfieldCorrectionPixelXCoordinate
flatfieldCorrectionGain
flatfieldCorrectionOffset
processingPathBpp
flatfieldAlgorithmBufferFormat
flatfieldAlgorithmBufferWidth
Sets the target pixel value for the gain (PRNU)
calibration.
Set flat field calibration sample size. (number of
lines to sum)
Performs Fixed Pattern Noise (FPN) calibration
by reducing to zero dark pixel current using a
pixel offset. PLEASE Grab image to enable it.
NoError
No Error.
FPN calibration failed.
The camera is busy and cannot perform the FPN
calibration.
The FPN calibration did not finished on time.
The camera cannot allocate the memory needed
for FPN calibration.
The FPN calibration was not able to reach the
targets.
Performs Photo Response Non Uniformity
(PRNU) calibration to a targeted, user-defined
value. PRNU calibration eliminates the difference
in responsivity between the most and least
sensitive pixel, creating a uniform response to
light. PLEASE Grab image to enable it
NoError
No Error.
PRNU calibration failed.
The camera is busy and cannot perform the
PRNU calibration.
The PRNU calibration did not finished on time.
The camera cannot allocate the memory needed
for PRNU calibration.
The PRNU calibration was not able to reach the
targets.
Save the calibration performed by
flatfieldCalibrationFPN and
flatfieldCalibrationPRNU to the active set.
Reset all FFC coefficients to pass-through. aka
Offset = 0; Gain = 1
Specifies the X coordinate of the Flat Field pixel
coefficient to access.
Sets the gain to apply to the currently selected
pixel.
Sets the offset to apply to the currently selected
pixel.
Processing path bits per pixel.
Flat Field Algorithm Buffer Format.
Mono8
Mono8.
Flat Field Algorithm Buffer Width.
1.00
Expert
DFNC
1.00
Guru
DFNC
1.00
Guru
DFNC
1.00
Guru
DFNC
1.00
Expert
DFNC
1.00
Expert
DFNC
1.00
Guru
DFNC
1.00
Guru
DFNC
1.00
Guru
DFNC
1.00
Invisible
DFNC
1.00
Invisible
DFNC
1.00
Invisible
DFNC
Operational Reference
53

Advertisement

Table of Contents
loading

Table of Contents