Troubleshooting
Overview
If an installation fails or experiences problems controlling and using the Linea SWIR GigE camera,
the user may perform diagnostics with the methods and tools provided to correct the problem.
The GigE Server status provides visual information on possible camera problems. The three states
are displayed in the following table with descriptions of possible conditions.
Note: An installation with no networking issue may still require optimization to perform to
specification.
Device Not Available
GigE Server
Tray Icon:
Note: It will
A red X will remain over the
take a few
GigE server tray icon when
seconds for the
the camera device is not
GigE Server to
found. This indicates a
refresh its state
network issue where there is
after any
no communication with the
change.
camera.
Problem Type Summary
Camera problems are either installation or setup related where the camera is found but not
controllable. Additionally the camera may be properly installed but network optimization is required
for maximum performance.
Device Not Available
A red X over the GigE server tray icon indicates that the camera device is not found. This
indicates either a major camera fault or condition such as disconnected power, or a network issue
where there is no communication.
Review section
steps.
Refer to Teledyne DALSA's Network Imaging manual to review networking details.
The camera cannot acquire a DHCP.
In multiple NIC systems where the NIC for the camera is using LLA mode, ensure that no
other NIC is in or switches to LLA mode. It is preferable that the Teledyne DALSA DHCP
server is enabled on the NIC used with the camera instead of using LLA mode, which
prevents errors associated with multiple NIC ports.
Verify that your NIC is running the latest driver available from the manufacturer.
124
Troubleshooting
Device IP Error
The GigE server tray icon
shows a warning when a device
is connected but there is some
type of IP error.
Figure 79: GigE Server Status
Using Linea SWIR GigE with the Sapera API
Device Available
The GigE server tray icon when
the device is found. The camera
has obtained an IP address and
there are no network issues.
Optimization may still be
required to maximize
performance.
to verify required installation