Graphical User Interface
Abort: Immediately stops all movement and aborts all tasks started using the buttons in the
"Build Platform" pane.
ReHome: Moves the vat to its lowest position.
Move Up/Move Down: Press and hold to move the vat in either direction. Release to stop.
Move Up by.../Move Down by...: Enter a value (in inches) in the adjacent field, and tap
either button to move the vat up or down by the specified distance.
Go To...: Enter a positive value (in inches) in the adjacent field, and tap to move the vat to
that position.
Update Status: Verifies if the shutter is open or closed. Reads the correct state of the
shutter and updates the Open Shtr/Close Shtr button if required.
Open Shtr/Close Shtr: Toggles the laser shutter open and closed. If the shutter is closed,
the button displays "Open Shtr." If the shutter is open, the button displays "Close Shtr."
Figure 28: VAT Pane
Figure 29: Laser Pane
© Copyright 2020 Stratasys. All rights reserved.
Optowave Laser Control Panel