Fault Codes
Fault Code Fault Message
5009
5010
5501
System I/O
6001
6002
6501
Lasers
8001
8002
8003
8004
Description
Resin level out of range
RL Insufficient
even with Vat at end of
Resin REFILL VAT
travel.
RL Vat leveling
Levelling position lost.
position lost
RL cmd parameter
Invalid parameters used.
out of range
E-Stop
E-stop activated.
Door Open
Door opened unexpectedly. Close chamber door.
System IO cmd
parameter out of
Invalid parameters used.
range
Laser Diode
Temperature Too
System overheated.
High
Laser Cooling
Internal Error
Loop Error
Laser Head
Temperature Too
System overheated.
High
Laser Head
Temperature Too
System too cold to start.
Low
© Copyright 2020 Stratasys. All rights reserved.
Table 1: Fault Codes
Resolution
Refill vat.
Manually move vat until
resin level values are in
range, then relevel. Contact
Technical Support if fault
persists.
Check move parameters
being used.
Reset E-Stop after
correcting cause.
Check command and
reissue.
Allow laser to cool down
before attempting to restart.
Contact Technical Support.
Allow laser to cool down
before attempting to restart.
Bring environment within
operating range before
attempting start.