Fault Codes
Fault Code Fault Message
3006
3007
3008
3009
3010
3011
3012
3013
3014
3015
3016
Description
RCT Sampled
count not moving
Recoater may be jammed.
as expected
RCT Vacuum
Possible obstruction or
sensor high
resin in vacuum line.
RCT Entire move
Move task taking too long.
timeout - 45 secs
RCT Unsafe move
Attempt to move recoater
- Elevator in way
while elevator is in the way.
RCT Homing -
unexpected
Recoater may be jammed.
encoder stoppage
Recoater may have moved
RCT Unexpected
too far beyond home, or
negative position
position sensor moved.
RCT DynPosn
Recoater may need
initial stop out of
rehoming.
range
Move task not possible
RCT Recoater not
because recoater is not
homed
homed.
RCT DynP limit
Recoater unexpectedly ran
found
into hard (sensor) limit.
RCT Vacuum Fault
Possible obstruction or
> 15secs
resin in vacuum line.
RCT Invalid
Invalid speed value.
DynPos speed (0)
© Copyright 2020 Stratasys. All rights reserved.
Table 1: Fault Codes
Resolution
Check for obstructions,
unexpected load or binding.
If none found, contact
Technical Support.
Contact Technical Support.
Reattempt move. Contact
Technical Support if fault
persists.
Raise elevator out of way
before attempting to move
recoater.
Check for obstructions,
unexpected load or binding.
If none found, contact
Technical Support.
Ensure recoater position
sensor (home position) is
not loose; Manually move
recoater away from home
and attempt to rehome.
Contact Technical Support
if fault persists.
Rehome axis. Contact
Technical Support if fault
persists.
Rehome recoater before
reattempting move task.
Limit sensor may have
come loose. Contact
Technical Support.
Contact Technical Support
Use valid speed for move
task (0 is invalid).