10002
Power Failure
1. In the event of a power failure, the UPS will automatically supply power to the V650 Flex. If
a build is in progress, it will continue until the UPS battery charge drops below 66%, at
which point the build will be paused by software. The build will remain paused until power is
restored, and the UPS battery charge has reached 75%, at which point the build will
automatically resume.
2. If power is not restored, and the UPS battery level drops below 25%, software will abort the
build, turn off the laser, and the UPS will continue to supply power to the V650 Flex until its
battery is drained. If the build is aborted, it must be restarted,
3. If power is unlikely to be restored before the UPS battery drains, you may choose to
manually abort the build and shut down the machine.
Xy2 Inhibit Bad
Argument
Motif Mode Bad
Argument
Raster Mode Not
Supported
Job Timer Bad
Argument
Output Draw List
Bad Argument
Jump Mark List
Bad Argument
Corrupt build file
Job too tall for
current setup!
Note:
With the laser on, the UPS will supply power for approximately 15 minutes before
dropping below 66% and pausing the build.
© Copyright 2020 Stratasys. All rights reserved.
Table 1: Fault Codes
Description
Internal Error
Internal Error
Internal Error
Internal Error
Internal Error
Internal Error
Corrupt build file
Job too tall for machine - or
machine limits set too
conservatively.
Resolution
Contact Technical Support
Re-prepare build file. Check
build parameters.
Contact Technical Support
to reset limits.
Page 141