Fault Codes
Fault Code Fault Message
1003
1004
1005
1006
1007
Elevator
2001
2002
2003
2004
2005
2006
2007
2008
2009
Description
No move tasks possible,
No devices homed
because no motion axes are
homed
Undefined
Undefined
PLC connection
Connection to PLC failed
failed
Unable to
Automatic attempt to
reconnect
reconnect with PLC failed
ELV Initial homing
timeout
ELV Reverse
Homing elevator is taking
homing timeout
too long.
ELV Reapproach
homing timeout
ELV DynP limit
Elevator ran into hard
found
(sensor) limit.
ELV Unsafe jog -
Attempt to move elevator
Recoater in way
while recoater is in the way.
ELV Ctrio cmd
Internal Error
error
ELV Sampled
count not moving
Elevator may be jammed.
as expected
ELV Entire move
Move task taking too long.
timeout - 75 secs
ELV Homing
Attempt to home elevator
unsafe - Recoater
while recoater is in the way.
in way
© Copyright 2020 Stratasys. All rights reserved.
Table 1: Fault Codes
Resolution
Rehome all axes before
reattempting task.
Check network cables
(internal device network).
Check for electrical noise
Check for obstructions,
unexpected load or binding
that may prevent elevator
from homing.
Limit sensor may have
come loose. Contact
Technical Support.
Move recoater out of the
way before attempting to
move elevator.
Contact Technical Support
Check for obstructions,
unexpected load or binding.
If none found, contact
Technical Support.
Reattempt the move.
Contact Technical Support
if fault persists.
Move recoater out of the
way before attempting to
move elevator