NEC NEAX 2000 IPS Maintenance Manual page 109

Internet protocol server
Hide thumbs Also See for NEAX 2000 IPS:
Table of Contents

Advertisement

B
CM40
Specify the RS port to make effective the pari-
ty check.
NOTE:
When using MP RS-232C port for
MAT, set the initial data.
Specify the kind of parity for the RS port.
NOTE:
When using MP RS-232C port for
MAT, set the initial data.
Specify the stop bit for the RS port.
NOTE:
When using MP RS-232C port for
MAT, set the initial data.
Specify the DTR signal sent to terminal for the
RS port.
NOTE:
When using MP RS-232C port for
MAT, set the initial data.
Specify the RTS signal sent to terminal for the
RS port.
NOTE:
When using MP RS-232C port for
MAT, set the initial data.
Specify the data speed of the RS port.
NOTE:
When you communicate with the
modem of PN-CP24-B/PN-CP24-C/
PN-CP24-D/PN-CP27-A/PN-
CP27-B, be sure to set the data
speed of RS1 port as 4800 bps or
more (1200 bps and 2400 bps are
not available).
END
DESCRIPTION
CHAPTER 1 MAINTENANCE SERVICE FEATURES
Y=02
(1)
0: RS0 port
1: RS1 port
(2)
0 : Effective
1 : Ineffective
Y=03
(1)
0: RS0 port
1: RS1 port
(2)
0 : Even parity
1 : Odd parity
Y=04
(1)
0: RS0 port
1: RS1 port
(2)
0 : 1-Stop bit
1 : 2-Stop bit
Y=05
(1)
0: RS0 port
1: RS1 port
(2)
0 : Low
1 : High
Y=06
(1)
0: RS0 port
1: RS1 port
(2)
0 : Low
1 : High
Y=08
(1)
0: RS0 port
1: RS1 port
(2)
1
2
3
4
5
NONE : 9600 bps
– 99 –
VoIP LOG COLLECTION
DATA
: 1200 bps
: 2400 bps
: 4800 bps
: 9600 bps
: 19200 bps
NWA-008847-001 Rev.3.0
a6ch1001.fm
JULY/01/2006

Advertisement

Table of Contents
loading

Table of Contents