D
CM42
Assign the number of stations in line
lockout to give MN (minor) alarm.
Assign the number of detected faulty
trunks to give MN (minor) alarm.
[Australia Only]
Assign the number of detected faulty
trunks to give MJ (major) alarm.
[Australia Only]
END
NOTE 1:
Even if the external alarm is set as MN or MJ alarm for system initialized (1st data=01), no
alarm is output in the case of Power On, Reset key operated, initialization from the MAT/CAT,
and initialization by MP SW3 switch selection.
NOTE 2:
The External Alarm Kind for "Number of faulty trunks was more than predetermined number"
is fixed as MN or MJ by CM42>06, 07. When CM42>06, 07 is assigned, the 2nd data of CMEA
Y=2 simply means the fault information is to be registered into Fault Memory. In this case, Ex-
ternal Alarm kind cannot be changed.
NOTE 3:
The External Alarm Kind for "Number of lockout stations was more than predetermined num-
ber" is fixed as MN. The 2nd data of CMEA Y=2 simply means the fault information is to be
registered into Fault Memory.
In this case, External Alarm Kind cannot be changed.
NOTE 4:
If Virtual CSH for WLAN detects a communication failure between the CSH and SIP server, by
a health check, the fault kind "2B" is registered as fault information.
NOTE 5:
The fault information of the fault kind "2C"/"3C" is also registered when a fault has occurred/
been restored in OAI mode. The fault information to be registered then is as follows.
[Series 3600 software required]
• The fault kind "2C" (LAN application fault occurred)
a) ABOUT/RLRQ (U-ABOUT/RLRQ reception)
b) Fault detection by healthcheck (healthcheck IP T.O.)
• The fault kind "3C" (LAN application returned to normal condition)
a) Association establishment (AARQ reception)
DESCRIPTION
CHAPTER 1 MAINTENANCE SERVICE FEATURES
(1)
01
(2)
01-99: Number of lockout stations
(1)
06
(2)
01-99: Number of Line Fault trunk
(1)
07
(2)
01-99: Number of Line Fault trunk