NEC NEAX 2000 IPS Maintenance Manual page 67

Internet protocol server
Hide thumbs Also See for NEAX 2000 IPS:
Table of Contents

Advertisement

A
Assign the PBX number and Originating
CME3
Point Code for each center and local office.
Assign which kind of fault information is
CMEA
stored into the fault information memory,
and which kind of alarm is indicated.
Specify the alarm kind sent automatically
to the Centralized MAT.
Specify the destination of fault information.
Specify the Point Code of the center office
as the Destination Point Code (DPC) which
fault information is sent to.
END
DESCRIPTION
CHAPTER 1 MAINTENANCE SERVICE FEATURES
• Y=02
(1) 0000-1023: PBX No.
(2) 00001-16367: Point Code set by
• Y=2
(1) See
"FAULT MESSAGE"
(2) CHAPTER 1.
• Y=3
(1) 00 : MJ alarm
01 : MN alarm
02 : - - alarm
(2) 0
: Send
1
: Not sent
• Y=4
(1) 01 : Destination of fault information
(2) 2
: 2400 IPX MAT or Centralized
MAT
3
: 2400 IPX MAT or Centralized
MAT and RMAT
• Y=4
(1) 05: Destination Point Code of fault
information
(2) 00001-16367: Point Code of center
– 57 –
CENTRALIZED MAT
DATA
CMA7 Y=01
of
Page 10
office
NWA-008847-001 Rev.3.0