NEC NEAX 2000 IPS Maintenance Manual page 184

Internet protocol server
Hide thumbs Also See for NEAX 2000 IPS:
Table of Contents

Advertisement

CARD NAME
PN-AP00-B
RUN lamp is not
(AP00/DBM)/
flashing
PN-AP00-D
(AP00)
PN-BRTA
RUN lamp is not
(BRT)
flashing
ALM lamp is on
Remedial Action on Each Lamp Status
LAMP
FAULT
STATUS
CONTENT
Abnormal opera-
tion of AP00/
DBM card
Abnormal opera-
tion of BRT card
Transmission line
fault
CHAPTER 2 TROUBLESHOOTING
FAULT DIAGNOSIS AND TROUBLESHOOTING
REMEDIAL ACTION
Confirm the programming data:
1
CM05.
Check to see if the SENSE switch is
2
set as per the AP Number (04-15,
20-31) assigned by CM05.
Reset the MB switch.
3
(Down Up Down)
Check the setting of SW1.
4
SW1-1: ON
SW1-2: ON
SW1-3: ON
If the fault cannot be cleared,
5
replace the card.
Confirm the programming data:
1
CM05, CM07 Y=02.
Check to see if the SENS switch is
2
set as per the AP Number (04-15)
assigned by CM05.
Reset the MB switch.
3
(Down Up Down)
If the fault cannot be cleared,
4
replace the card.
Confirm circuit line status.
1
Confirm PSTN line status.
2
– 174 –
Continued on next page
NWA-008847-001 Rev.3.0
a6ch2001.fm
JULY/01/2006