NEC NEAX 2000 IPS Maintenance Manual page 189

Internet protocol server
Hide thumbs Also See for NEAX 2000 IPS:
Table of Contents

Advertisement

CARD NAME
PN-CFTC/
RUN lamp is not
PN-CFTC-A
on
(CFT)
Remedial Action on Each Lamp Status
LAMP
FAULT
STATUS
CONTENT
Abnormal opera-
tion of CFT card
CHAPTER 2 TROUBLESHOOTING
FAULT DIAGNOSIS AND TROUBLESHOOTING
REMEDIAL ACTION
Confirm the programming data:
1
CM05 Y=0/Y=1, CM07 Y=01.
Check to see if the SENSE switch is
2
set as per the AP Number (04-15,
20-31) assigned by CM05 Y=0.
Reset the MB switch.
3
(Down Up Down)
If the fault cannot be cleared,
4
replace the card.
– 179 –
Continued on next page
NWA-008847-001 Rev.3.0
a6ch2001.fm
JULY/01/2006

Advertisement

Table of Contents
loading

Table of Contents