NEC NEAX 2000 IPS Maintenance Manual page 28

Internet protocol server
Hide thumbs Also See for NEAX 2000 IPS:
Table of Contents

Advertisement

(2)
To clear the MJ/MN alarm by external key
START
Assign the card number for External Key
CM10
Interface (PN-DK00) to the desired LEN.
NOTE1:
We recommend the setting of card
number for External Key Interface
by CM14, when using Series 3200
R6.2 software or later.
NOTE2:
The card number of the External
Key Interface (PN-DK00) must be
assigned to the first LEN (LEVEL
0) and third LEN (LEVEL 2) of
each card slot.
NOTE3:
Circuit No. 3 of E963 is used for
built-in External Key Interface of
MP card by setting CM61.
Assign the card number for External Key
CM14
Interface (PN-DK00) to the desired LEN.
[Series 3200 R6.2 software required]
NOTE1:
The card number of the External
Key Interface (PN-DK00) must be
assigned to the first LEN (LEVEL
0) and third LEN (LEVEL 2) of
each card slot.
NOTE2:
Circuit No. 3 of E963 is used for
built-in External Key Interface of
MP card by setting CM61.
Assign the function of MJ/MN alarm
CM61
clear key to the external key.
END
DESCRIPTION
CHAPTER 1 MAINTENANCE SERVICE FEATURES
(1)
000-763: LEN
(2)
E900-E963:
Card No. of External Key Interface
(PN-DK00)
For PIM0/1: E900-E915
For PIM2/3: E916-E931
For PIM4/5: E932-E947
For PIM6/7: E948-E963
(1)
XX ZZZ: LEN
XX : 00-59: FP No.
ZZZ: 000-127: Port No.
(2)
E900-E963:
Card No. of External Key Interface
(PN-DK00)
For FP No.00: E900-E915
For FP No.01: E916-E931
For FP No.02: E932-E947
For FP No.03: E948-E963
Y=30
(1)
XX Z
XX : 00-63 : Card No. of PN-DK00
Z
: 0-3
633 : MP built-in External Key Interface
(2)
00: MJ/MN alarm clear key
– 18 –
FAULT MESSAGE
DATA
: Circuit No.
NWA-008847-001 Rev.3.0