CARD NAME
PN-DAIC
RUN lamp is not
(DAIC)
flashing
LINK lamp is not
on
RED lamp is on
RMT lamp is on
Remedial Action on Each Lamp Status
LAMP
FAULT
STATUS
CONTENT
Abnormal opera-
tion of DAIC card
Layer 2 link con-
nection failure
between DAIA
and DAIB
PCM signal loss or
Frame Alignment
signal loss
Remote alarm
CHAPTER 2 TROUBLESHOOTING
FAULT DIAGNOSIS AND TROUBLESHOOTING
REMEDIAL ACTION
Reset the MB switch.
1
(Down→Up→Down)
If the fault cannot be cleared,
2
replace the card.
Check to see if the cable between
1
DAIA and DAIB is correctly con-
nected.
Reset the MB switch.
2
(Down→Up→Down)
Check to see if the cable between
3
DAIC cards is correctly connected.
Check to see if the cable between DAIC
cards is correctly connected.
Check to see if the cable between DAIC
cards (sending side) is correctly con-
nected.
– 182 –
Continued on next page
NWA-008847-001 Rev.3.0