NEC NEAX 2000 IPS Maintenance Manual page 207

Internet protocol server
Hide thumbs Also See for NEAX 2000 IPS:
Table of Contents

Advertisement

CARD NAME
PN-SC03-B
RUN lamp is not
(CSH/ICH)/
flashing
PN-SC03-C
(CSH)
DOPE 0-7 lamp is
not on
PN-2COTD/
LF lamp is on
PN-2COTE
(COT)
PN-4COTE
LF lamp is on
(COT)
[For Australia]
PN-6COTJ
LF lamp is on
(COT)
[For Australia]
Remedial Action on Each Lamp Status
LAMP
FAULT
STATUS
CONTENT
Abnormal opera-
tion of CSH card
D-channel link is
not connected
between CSH and
CSI
Transmission line
fault
Transmission line
fault
Transmission line
fault
CHAPTER 2 TROUBLESHOOTING
FAULT DIAGNOSIS AND TROUBLESHOOTING
REMEDIAL ACTION
Confirm the programming data:
1
CM05 Y=0.
After confirmation of CM05, reset
2
the system (Push the SW1 of MP).
Check to see if the SENSE switch is
3
set as per the AP Number (04-15,
20-31) assigned by CM05 Y=0.
Reset the MB switch.
4
(Down Up Down)
If the fault cannot be cleared,
5
replace the card.
Confirm the programming data:
1
CM06 Y=10
Confirm if the corresponding CSI
2
card is removed.
If the fault cannot be cleared,
3
replace the card.
Search for a line fault by CMB0
1
Y=1 or CMF5 Y=0.
Check to see if the trunk line is
2
faulty.
Search for a line fault by CMB0
1
Y=1 or CMF5 Y=0.
Check to see if the trunk line is
2
faulty.
Search for a line fault by CMB0
1
Y=1 or CMF5 Y=0.
Check to see if the trunk line is
2
faulty.
– 197 –
Continued on next page
NWA-008847-001 Rev.3.0
a6ch2001.fm
JULY/01/2006

Advertisement

Table of Contents
loading