NEC NEAX 2000 IPS Maintenance Manual page 85

Internet protocol server
Hide thumbs Also See for NEAX 2000 IPS:
Table of Contents

Advertisement

(4)
To match the MP program version of Flash ROM 0 (outdated side) and Flash ROM 1 (upgraded
side), do the following programming
START
CM0C
For each Site, copy the MP program of Flash
ROM 1 (upgraded side) to the Flash ROM 0
(outdated side).
NOTE1:
NOTE2:
NOTE3:
END
(5)
To read the status of MP program downloading, do the following programming.
START
CM0C
For each Site, read the status of MP program
download.
NOTE1:
NOTE2:
END
DESCRIPTION
You can clear the previous MP pro-
gram by this data setting.
While the MP program is being
downloaded, the second data 0 can-
not be assigned. If you do that,
"WAIT, BUSY NOW" is displayed.
When the communication between
Main Site and Remote Site cannot
operate normally, "HARDWARE
ERROR" is displayed.
DESCRIPTION
If you set this data other than while
the MP program download is exe-
cuted, "NONE" is displayed.
Display example:
If you are downloading the third file
of 11 MP program files, "00030B"
is displayed as the second data.
(File type 00=MP program file).
When the communication between
Main Site and Remote Site cannot
operate normally, "HARDWARE
ERROR" is displayed.
CHAPTER 1 MAINTENANCE SERVICE FEATURES
Y=52
(1)
XX03
XX: 00: Main Site No.
01-30: Remote Site No.
(2)
0 : To copy
1 : Not copied
Y=52
(1)
XX04
XX: 00: Main Site No.
01-30: Remote Site No.
(2)
XX YY ZZ
XX: File type
00: MP program file
YY: Downloading file No.
ZZ : Total number of files
– 75 –
MP PROGRAM DOWNLOAD (FTP)
DATA
DATA
NWA-008847-001 Rev.3.0
a6ch1001.fm
JULY/01/2006

Advertisement

Table of Contents
loading